background image

Model: I31-NG3
  

I31-LPG3

Owners &

Installation

 

Man

ual

09/10/12

LISTINGS AND CODE APPROVALS

These gas appliances have been tested in 
accordance with AS4553, NZS 5262 and 
have been certifi ed by the Australian Gas 
Association for installation and operation as 
described in these Installation and Operating 
Instructions.

Your unit should be serviced annually by 
an authorised service person.

918-001d

I31-3 Gas Inbuilt

FOR YOUR SAFETY
What to do if you smell gas:

 

Do not try to light any appli-
ance

 

Do not touch any electrical 
switch: do not use any phone 
in your building.

  Immediately call your gas 

supplier from a neighbour's 
phone. Follow the gas sup-
plier's instructions.

 

If you  cannot reach your gas 
supplier, call the fi re depart-
ment.

WARNING:  
Improper installation, adjustment, altera-
tion, service or maintenance can cause 
injury or property damage. Refer to this 
manual. For assistance or additional in-
formation consult an authorised installer, 
service agency or the gas supplier.

FOR YOUR SAFETY
Do not store or use gasoline or other fl am-
mable vapours and liquids in the vicinity of 
this or any other appliance.

Installation and service must be performed 
by an authorised installer, service agency or 
the gas supplier.

PLEASE KEEP THESE INSTRUCTIONS

FOR FUTURE REFERENCE

Summary of Contents for I31-LPG3

Page 1: ...useanyphone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire depart ment WARNING Improper installation adjustment altera tion service or maintenance can cause injury or property damage Refer to this manual For assistance or additional in formation consult an authorised installer ...

Page 2: ...arm of a fireplace at the flick of a switch The model I31 3 of this series has been approved by Australian Gas Association for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace...

Page 3: ... 1 panel 10 Flush Louvres 10 Optional Bay Door 3 panel 11 Bay Louvres 11 Hampton Cast Faceplate Installation 12 Hampton Cast Grill Installation 13 Barossa Curved Front 14 Optional Remote Control 15 Optional Wall Thermostat 15 Wiring Diagram 15 Operating Instructions Operating Instructions 16 Lighting Procedure 16 Shutdown Procedure 16 First Fire 16 Automatic Convection Fan Operation 16 Normal Oper...

Page 4: ...RATION OPERATE WITH PANELS COVERS OR GUARDS REMOVED FROM THIS APPLIANCE ENCLOSE THIS APPLIANCE DO NOT MODIFY THIS APPLIANCE NEAR THIS APPLIANCE DO NOT 908 602a Electrical Conforms to AS3100 240V 50Hz 1 0 amp Max Serial Number 908 062f Regency Gas Fireplace Model Gas Type NG LPG NG LPG Model AGA 5815G 5498G AS4553 5815 5815 5498 5498 P36 NG P36 LPG I31 3NG I31 3LPG Gas Consumption 33mj 31mj 31mj 31...

Page 5: ...ter to a chim ney and flue to the outside of the building envelope Neverfluetoanotherroom Make sure that the flue is properly sized and is of adequate height to provide the proper draft 6 Inspect the flueing system annually for blockage and any signs of deterioration 7 Anysafetyglassremovedforservicingmust bereplacedpriortooperatingtheappliance 8 To prevent injury do not allow anyone who is unfami...

Page 6: ...ifferent Please refer to the Zero Clearance Kit Manual for details Mantel Clearances with Bay and Flush Louvres in Masonry Installation MINIMUM FIREPLACE DIMENSIONS The minimum fireplace dimensions for the Regency gas space heater are shown in the following diagrams Note A non combustible mantel may be installed at a lower height if the fram ing is made of metal studs covered with a non combustibl...

Page 7: ...Install to AS5601 2004 Australia NZS 5261 New Zealand Combustion and Ventilation Air WARNING This appliance needs freshairforsafeoperationandmust be installed with provisions for ad equate combustion and ventilation air available to the room in which it is to be operating Air for combustion is drawn in through the front of the unit therefore the front of the unit must be kept clear of any obstruct...

Page 8: ...switch acts as a safety shut off to preventabuild upofcarbonmonoxide Ifthe flue is blocked or has no draw the switch will automatically shut off the supply of gas within 5 10 minutes Tampering with the switch can result in carbon monoxide CO poisoning and possible death If the heater turns off because of lack of draft during the spillage test check for the cause and if necessary rectify The therma...

Page 9: ...e to ensure proper light off make sure flame flows smoothly from one end of burner to the other If there is any flame hesitation check that area for any blockage of the burner port 12 Install flush glass and optional bay glass as D 02 46 E 02 47 F 02 48 per instructions in this manual G 02 44 C 02 56 A 02 43 B 02 45 A 02 43 B 02 45 E 0 2 4 7 C 02 56 A 02 43 B 02 45 F 02 48 D 02 46 G 02 44 E 0 2 4 ...

Page 10: ...Place the trim on the assembled faceplate panels aligning the wire connections from the switches with the notch on the left side panel 5 Hookup the 3 Fan Switch wires to the fan switch on the left side trim Diagram 3 WARNING The 3 wires are to the Fan and the 2 wires are to the ON OFF burner switch DO NOT con nect to the wrong switch WARNING Ensure that the wires do NOT touch the firebox INSTALLAT...

Page 11: ...tion fit if the louvre needs to be adjusted bend the bracket out as shown in the diagram 3 Place the bottom of the flush glass behind the bottom glass trim 4 Secure the glass with the two glass clips at the top corners of the glass Secure glass clips with the screws provided Do not over tighten as this could break the glass 5 Slide in the top glass trim under the spring clips 2 Position2magnetsont...

Page 12: ...ness thruthehole provided and connect them with the wire connectors from the fan speed control 7 Insert wires into the strain relief and install into switch box assembly Switch Box Assembly Boss on rear left side piece 8 Place the switch box assembly over the boss on the rear left side piece and secure with one screw NOTE Do not install Cast Faceplate when unit is installed into a Zero Clearance U...

Page 13: ...go peel the sticker from the back of the logo and place it centered on the bottom left hand corner of the faceplate Regency Logo Left Hand Side Faceplate HAMPTON CAST GRILL INSTALLATION Note The top louver should be placed with the curved cut out facing up Before the grills are installed a grill stop bracket needs to be put in place 1 The grill stop bracket is installed in the bottom left corner j...

Page 14: ...2 Pull down louver 3 Fix brackets onto firebox one on each side using 1 screw per side 4 Fit plates on back of screen into brackets on top of firebox Press in to secure from top Secure bracket with screw 5 Secure bottom of screen using 1 screw on each side into the brackets fixed onto the firebox in step 3 Brackets on firebox 6 Close louver INSTALLATION Secure louver by using 2 screws Secure with ...

Page 15: ...d directly into a properly grounded three prong recepta cle Do not cut or remove the grounding prong from this plug Noelectricalpowersupplyisrequiredforthegas controltooperate However a240VA C power supply is needed for the fan blower operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges OPTIONAL WALL THERMOSTAT Awallthermostatmaybeinstalledifdesired U...

Page 16: ...not force 4 Disconnect all electric power and gas to the appliance if service is to be performed FIRST FIRE The first fire in your stove is part of the paint curing process To ensure that the paint is properly cured it is recommended that you burn your fireplace for at least four 4 hours the first time you use it with the fan on When first operated the unit will release an odour caused by the curi...

Page 17: ...as control knob counterclockwise to ON 6 Use rocker switch to operate main burner Thisappliancemustbeinstalledinaccordancewithlocalcodes ifany ifnone followtheNationalFuelGasCode ANSIZ223 1 NFPA54 orNaturalGasandPropaneInstallationsCodes CSAB149 1 Australia AS5601 2004 NewZealand NZS5261 2 Turn off all electric power to the appliance if service is to be performed a qualified service technician For...

Page 18: ...t to discolour check the door gasket seal and replace if necessary LOG REPLACEMENT The unit should never be used with broken logs Turn off the gas valve and allow the unit to cool beforeopeningdoortocarefullyremovethelogs The pilot light generates enough heat to burn someone If for any reason a log should need replacement you must use the proper replace ment log The position of these logs must be ...

Page 19: ...y Push the tray to the left and lift up 8 Remove the 11 screws holding the Access Panel in place 9 Remove the Fan Air Duct by removing 4 screws 2 per side 10 Unplug the black wires from the fan motor from inside the stove 11 LiftFanAssemblyoffofthe2pins tipforward and pull through firebox opening 12 Disconnect green wire from power cord Replacing fan Reverse above steps Hint for pushing fan down o...

Page 20: ... continues open aeration shutter on burner Note To clean glass remove and wipe with cloth or paper towel Check gas pressure Clean out carbon spider webs lint etc from burner area Check and replace fan assembly Check and replace fan switch Check and replace thermodisc Relight follow lighting procedure completely Adjust pilot Thermopile check and replace if faulty Replace thermocouple MAINTENANCE TH...

Page 21: ...h Bracket 12 910 220 Spill Switch 13 Levelling Bolts 5 16 x 3 Hex Head 948 216 Logo Plate 918 001 Manual Regency 22 402 920 Flush Louvre set Black Top Bottom 402 922 Flush Louvre set Gold Black Top Bottom 402 924 Flush Louvre set Steel Black Top Bottom 26 400 990 Bay Louvre set Black Top Bottom 400 992 Bay Louvre set Gold Black Top Bottom 400 993 Bay Louvre set Steel Black Top Bottom 400 945 Brick...

Page 22: ...fice LPG 52 58 910 424 Pilot ON OFF Extension Knob 59 910 426 Flame HI LOW Extension Knob 60 402 019 Grate Assembly 62 402 537 Burner Assembly NG LPG 63 910 034 Pilot Assy NG 3 flame convertible top 910 035 Pilot Assy LPG 3 flame convertible top 65 Burner Shroud Gasket 69 402 935 Log Set 402 572 Ember Package 86 910 386 Thermocouple 87 910 341 Thermopile 92 902 267 Rear Log 93 902 231 Left Top Log...

Page 23: ...eplate Trim Left Assy Regular 403 913 Faceplate Trim Compelte Oversize 141 Faceplate Side Right Oversize 142 Faceplate Top Oversize 143 Faceplate Side Left Oversize 401 524 Trims Packaged Oversize 144 Faceplate Trim Right Oversize 145 Faceplate Trim Top Oversize 146 Faceplate Trim Left Assy Oversize 172 400 950 Hearth Trim 1 Regular 320 940 Hearth Trim 1 Oversize 176 400 926 Hearth Trim 2 Regular ...

Page 24: ...lass 110 902 183 Bay Brick Panel 400 935 Bay Door Trim Set Gold 400 989 Bay Door Trim Set Steel 111 Bay Door Trim Top 112 904 196 1 Round Ceramic Magnet 113 Bay Door Trim Bottom Flush Door 149 400 531 P Flush Screen Packaged Aust Only 402 515 P Complete Flush Front Assembly 107 936 243 Gasket 153 Glass Side Trim 154 Flush Glass 156 936 238 Flush Glass Gasket 157 Screw 10 24 x 1 2 Truss Hd Machine ...

Page 25: ...nob Black Cast Surround 201 Cast Faceplate Right 202 Cast Faceplate Top 203 Cast Faceplate Left 205 Flush Glass Frame 194 Mounting Flange 207 402 981 Cast Grill Set Top Bottom Black Metallic 402 986 Cast Grill Set Top Bottom Black Enamel Not available as a replacement part HAMPTON CAST FACEPLATE ASSEMBLY Part Description 202 205 187 189 188 203 195 194 194 207 201 PARTS LIST ...

Page 26: ...___________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ________________...

Page 27: ...urchaser of a Regency Product The Warranty Lifetime Covered under the agreement are the following components Combustion chamber heat exchanger burner tubes logs embers glass thermal breakage and all gold plating against defective manufacture The above will be covered for parts and labour for the first five years and parts only thereafter Electrical components such as fans switches wiring thermodis...

Page 28: ...Printed in Canada Copyright 2009 FPI Fireplace Products International Ltd All rights reserved ...