15
Regency I31-3 Gas Fireplace Inbuilt
INSTALLATION
Thermostat Wire Table
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 240 V wires.
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
OPTIONAL REMOTE
CONTROL
Use the Optional Remote Control Kit approved
for this unit. Use of other systems may void
your warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting plate.
1)
Choose a convenient location on the wall
to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace to
that location. Use Thermostat Wire Table.
2)
Connect the two wires to the gas valve.
3)
Install a 9V alkaline battery in both receiver
and the transmitter. Install the receiver and
cover in the wall. The remote control is now
ready for operation.
Wire Size
Max. Length
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
15.24 m
9.75 m
6.10 m
3.66 m
2.71 m
WIRING
CAUTION:
Label all wires prior to
disconnection when
servicing controls.
Wiring errors can cause
improper and dangerous
operation.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged
(grounding) plug for your protection against
shock hazard and should be plugged directly
into a properly grounded three-prong recepta-
cle. Do not cut or remove the grounding prong
from this plug.
No electrical power supply is required for the gas
control to operate. However, a 240V A.C. power
supply is needed for the fan/blower operation.
Caution: Ensure that the wires do not
touch any hot surfaces and are away
from sharp edges.
OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired. Use
chart below to determine thermostat wire length.
Note: Preferable if the thermostat is installed
on an interior wall.
Use a CSA, UCL or UL approved millivolt ther-
mostat, 250-750 millivolt rated. A non-anticipator
type thermostat must be used.
CAUTION
Do not connect the millivolt
remote control wires to
the 240V wires.
Gas
In
Pilot
Gas
Thermo-
couple
IN
Robertshaw
Valve
PIL
O
T
PIL
O
T
ON
O
F
F
O
F
F
VENT
HI
HI
LO LO
Gas
Pilot
Thermopile
Thermocouple
Electrode
Piezo Ignitor
To
Thermocouple IN
To
Pilot
Gas
Yellow
Orange
White
Pilot
Assembly
Thermostat
(Optional)
(Millivolt)
Remote
Receiver
(Optional)
(Millivolt)
Remote Transmitter
(Optional)
Flue Spill
Switch
(Auto Reset)
(Normally closed)
ON
OFF
Burner
ON
OFF
Brown
OUT Pressure Tap
IN
Pressure
Tap
Grounding
Lug Detail
Lockwasher
Fan ground
Power cord
ground wire
Star washer
Nut
Nut
#8 Ground Lug
Star washer
HIGH
OFF
LOW
Red
Black
Yellow/Green
Ground
Brown
(Live)
White
Molex
Connector
White
Red
Blue
(Neutral)
Fan Thermodisc
(Normally open)
240V AC
50 HZ
Terminal
Block
Green
Ground
Fan
Red/Black
Stripe