6
|
Regency Excalibur
®
P90-10 Zero Clearance Direct Vent Gas Fireplace
|
6
safety decal
This is a copy of the label that accompanies each
P90 Zero Clearance Direct Vent Gas Fireplace.
We have printed a copy of the contents here for
your review. The safety label is located on the
front inside base of the unit, visible when the
bottom louver is open.
NOTE:
Regency
®
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
Copy of Safety Decal for P90
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
309
309
DOOR SEAL: Please check that the door is properly sealed
FPI Fireplace Products International Ltd.
Delta, BC, Canada
DUPLICATE SERIAL NO.
Serial No./ No de serie
919-496a
Model/Modele:
P90-NG10
Model/Modele:
P90-LP10
Made in Canada/ Fabrique au Canada
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or
when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for
details.
Optional Fan (Part # 910-331) Optional Heat Wave Kit # 946-556 Optional Heat Release Kit # 946-570
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes
ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux
le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
For use with glass doors certified with the appliance only Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil
(
See Instruction Manual for
Detailed Instructions)
Minimum Clearances to Combustibles
/Degagement Minimum De Materiaux Combustibles
0" Clearance to
combustibles from:
Top, bottom, sides & rear of unit
Mantel Clearances from Top:
Min. 19" (483mm)
Side Wall Clearance
from Side Facing
6-1/2" (165mm)
Minimum Vent Clearances:
Horizontal Top 2-1/2" (64mm)
Horizontal Side 1-1/2" (38mm)
Horizontal Bottom 1-1/2" (38mm)
Alcove Clearances:
Max. Depth 36" (914mm)
Min. Width 72" (1829mm),
Min. Height 72" (1829mm)
6-1/2"
6-1/2"
W
all
W
all
19"
44" To Ceiling
NATURAL GAS:
Model P90-NG10
L
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
5"
WC (1.25 kPa)
3.8"
WC (0.95 kPa)
1.1"
WC (0.27 kPa)
# 34
DMS
18,200 Btu/h
(5.42 kW)
35,000 Btu/h
(10.26 kW)
0-4500 ft/pi
(0-1372 m)
APPAREIL FONCTIONNANT AU NATURAL GAZ
CONCU POUR ETRE POELE:
Modéle P90-NG10
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
é
é é
Pression à la tubulure d' chappement basse
é
Grandeur de l'injecteur
D bit Calorifique minimum selon
é
D bit Calorifique maximum selon
é
l'altitude
APPAREIL FONCTIONNANT AU GAZ PROPANE
CONCU POUR ETRE POELE:
Modéle P90-LP10
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
é
é é
Pression à la tubulure d' chappement basse
é
l'altitude
Grandeur de l'injecteur
D bit Calorifique minimum selon
é
D bit Calorifique maximum selon
é
l'altitude
Grandeur de l'injecteur
D bit Calorifique minimum selon
é
D bit Calorifique maximum selon
é
PROPANE:
Model P90-LP10
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Altitude
Orifice size
Minimum input
Maximum input
High Altitude
Orifice size
Minimum input
Maximum input
12"
WC (3.00 kPa)
11"
WC (2.74 kPa)
2.9"
WC (0.72 kPa)
0-2000 ft/pi
(0-610 m)
# 51
DMS
17,950 Btu/h
(5.26 kW)
35,000 Btu/h
(10.26 kW)
2000-4500
ft/pi (610-1372 m)
# 52
DMS
15,500 Btu/h
(4.54 kW)
31,000 Btu/h
(9.08 kW)
VENTED GAS FIREPLACE HEATER -
NOT FOR USE WITH SOLID FUELS.
NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
FOYER AU GAZ À ÉVACUATION -
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Listed:
VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour:
CANADA and U.S.A.
é
Certified to:
CAN/CGA-2.17-M91(R2009)
ANSI Z21.88-2014/ CSA 2.33-2014
Tested to:
4001172
Part #: 919-496a
Colour: Everything black on grey except what is highlighted is printed red.
Material: 2 ml silver matt polyester (DPM SMS)
Size: 100%
Dec.10/2014: Created decal.
Jan 26/15:
Rev. A updated Alcove width
*Printer:
Continue number sequence from
918-503
- do not restart at 0
ELECTRICAL SUPPLY/ALIMENTATION ELECTRIQUE: 115V_60HZ less than/moins de 2 AMP
For Use Only with Barrier (Part #792-920) Follow installation instructions. Utiliser uniquement avec l’écran ( n ° 792-920) Suivre les instructions d'installation.