installation
2
PTO30 / PTO30-1
919-038a
06/26/17
13.
Attach the label “This unit has been converted to LPG” near or on
top of the serial # decal.
14.
Replace yellow “NG” label with red “LPG” label.
Make appropriate gas connections.
12.
Remove Hi/Lo pressure regulator by removing 2 screws as shown
below.
Reverse steps to install LP pressure regulator. (Be sure diaphragm
and spring are removed.)
15.
Check all gas connections under normal operating pressure, for leaks,
with soapy water.
NOTE:
If soap bubbles, this would indicate a gas leak.
16.
Check inlet and outlet pressures.
17.
Check operation of fl ame control.
11.
Remove 6 screws on valve access cover.
HI/LO pressure
regulator
8.
Pull off the pilot cap to expose the pilot orifi ce. Using a 5/32" allen key,
remove pilot orifi ce and replace with LP pilot orifi ce.
7.
Remove burner orifi ce with a 1/2" wrench. Use another wrench to
hold on to the elbow behind the orifi ce. Discard orifi ce.
Install new NG orifi ce supplied with kit.
Repeat steps to install LP orifi ce.
9.
Re-install pilot cap.
10.
Adjust aeration accordingly - see manual for details.