Regency U28-2/U43-3 ULTIMATE Freestanding Gas Heater
7
INSTALLATION
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of
the following:
IMPORTANT:
SAVE THESE
INSTRUCTIONS
The ULTIMATE Freestanding Gas Stove must be
installed in accordance with these instructions.
Carefully read all the instructions in this manual
first. Consult the "authority having jurisdiction" to
determine the need for a permit prior to starting
the installation.
GENERAL SAFETY IN-
FORMATION
1)
The appliance installation must conform
with local codes or, in the absence of local
codes, with the current Canadian or National
Gas Codes, CAN1-B149 or ANSI-223.1
Installation Codes.
2)
The appliance when installed, must be elec-
trically grounded in accordance with local
codes, or in the absence of local codes with
the current National Electrical Code, ANSI/
NFPA 70 or CSA C22.1 Canadian Electrical
Code.
3)
This appliance is Listed for bedroom in-
stallations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
4)
This appliance is Listed for Alcove installa-
tions, maintain minimum Alcove clearances
as follows, minimum ceiling height of 66",
minimum width of 48" and a maximum depth
of 36".
5)
This unit is not approved for installation into
a mobile home.
6)
See general construction and assembly
instructions.
7)
This appliance must be connected to a vent
and terminate to the outside of the building
envelope. Never vent to another room or
inside a building.
8)
Inspect the venting system annually for
blockage and any signs of deterioration.
9)
Any safety glass removed for servicing must
be replaced prior to operating the appliance.
10)
To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fireplace.
11)
Wear gloves and safety glasses for protec-
tion while doing required maintenance.
INSTALLATION AND REPAIR
SHOULD BE DONE BY A QUAL-
IFIED SERVICE PERSON. THE
APPLIANCE SHOULD BE IN-
SPECTED BEFORE USE AND AT
LEAST ANNUALLY BY A PRO-
FESSIONAL SERVICE PERSON.
MORE FREQUENT CLEANING
MAY BE REQUIRED DUE TO
EXCESSIVE LINT FROM CAR-
PETING, BEDDING MATERIAL,
ETC. IT IS IMPERATIVE THAT
CONTROL COMPARTMENTS,
BURNERS AND CIRCULATING
AIR PASSAGEWAYS OF THE
APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES,
THE APPLIANCE SHOULD BE
LOCATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE AND
DRAPERIES.
WARNING: FAILURE TO INSTALL
THIS APPLIANCE CORRECTLY
MAY CAUSE A SERIOUS HOUSE
FIRE AND WILL VOID YOUR
WARRANTY.
C H I L D R E N A N D A D U LT S
SHOULD BE ALERTED TO THE
HAZARDS OF HIGH SURFACE
TEMPERATURES, ESPECIAL-
LY THE FIREPLACE GLASS,
AND SHOULD STAY AWAY TO
AVOID BURNS OR CLOTHING
IGNITION.
YOUNG CHILDREN SHOULD
BE CAREFULLY SUPERVISED
WHEN THEY ARE IN THE SAME
ROOM AS THE APPLIANCE.
CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD
NOT BE PLACED ON OR NEAR
THE APPLIANCE.
12)
Under no circumstances should this ap-
pliance be modified. Parts that have to be
removed for servicing should be replaced
prior to operating this appliance.
13)
Installation and any repairs to this appliance
should be done by a qualified service per
-
son. A professional service person should
be called to inspect this appliance annually.
Make it a practice to have all of your gas
appliances checked annually.
14)
Do not strike the glass door.
15)
Under no circumstances should any solid
fuels (wood, paper, cardboard, coal, etc.)
be used in this appliance.
16)
The appliance area must be kept clear and
free of combustible materials, (gases and
other flammable vapours and liquids).
17)
Do not connect this gas appliance to chimney
flue serving a separate sold-fuel burning
appliance.
18)
WARNING: Operation of this appliance
when not connected to a properly installed
and maintained venting system or tampering
with the blocked vent shut-off system can
result in carbon monoxide (CO) poisoning
and possible death.
19)
This appliance needs fresh air for safe op-
eration and must be installed so there are
provisions for adequate combustion and
ventilation air.