Regency CI1200 / CI1250 Wood Cast Insert
27
MAINTENANCE
Annual Maintenance
Completely clean out entire unit
Annually
Inspect air tubes, baffl es and bricks
Replace any damaged parts.
Adjust door catch / latch
If unable to obtain a tight seal on the door - replace door gasket seal.
Readjust latch after new gasket installed.
Paper Test
Test the seal on the loading door with a paper bill.
Place a paper bill in the gasketed area of the door on a cold stove–close the
door.
Try to remove the paper by pulling.
The paper should not pull out easily, if it does, try adjusting the door latch, if
that doesn't solve the problem replace the door gasket.
Inspect condition and seal of:
Glass Gasket
Door Gasket
Perform paper test - replace gasket if required
Check and lubricate door hinge + latch
Use only high temperature anti seize lube. (ie. never seize)
Check glass for cracks
Replace if required.
Clean blower motor
Disconnect power supply.
Remove and clean blower.
*DO NOT LUBRICATE*
Inspect and clean chimney
Annual professional chimney cleaning recommended.