Regency CI1203 / CI1253 Wood Cast Insert
| 5
5
|
safety decal
This is a copy of the label that accompanies each
CI1253 Wood Insert
. We have printed a copy
of the contents here for your review.
NOTE:
Regency units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
LISTED FACTORY BUILT FIREPLACE INSERT
CERTIFIED FOR USE IN CANADA AND U.S.A.
MODEL:
CI1250
TESTED TO:
ULC S628-M93 / UL 1482-2006 / ULC S627-00
WN # 16600
DO NOT REMOVE THIS LABEL
367
COMPONENTS REQUIRED FOR INSTALLATION: 5.5" (140mm) OR 6" (152MM) STAINLESS STEEL LINER. STANDARD ADAPTOR (171-932) OR OFFSET
ADAPTOR (171-936). STANDARD COMPONENT: FAN ELECTRICAL RATING: VOLTS 115, 60HZ.
DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE.
BUILD WOOD FIRE DIRECTLY ON HEARTH. OPERATE WITH FEED DOOR CLOSED, OPEN TO FEED FIRE ONLY. REPLACE GLASS ONLY WITH CERAM-
IC GLASS (5MM). INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY.
DO NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (MEASURED FROM INSERT BODY)
918-916d
MANUFACTURED BY:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC V4G 1H4
HOT WHILE IN OPERATION
DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY.
CONTACT MAY CAUSE SKIN BURNS.
READ ABOVE INSTRUCTIONS.
ADJACENT SIDEWALL A) 15in / 380mm
MANTLE
B) 20in / 510mm
TOP FACING
C 14in / 355 mm
SIDE FACING
D) 7.375in / 185mm
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS. INSTALL AND USE ONLY
IN MASONRY FIREPLACE OR FACTORY BUILT FIREPLACE.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.
JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC
2017 2018 2019 2020 2021
(Duplicate Serial #)
MADE IN CANADA
367
DATE OF
MANUFACTURE
INSTALLER ET UTILISER SELONS LES INSTRUCTIONS DU FABRICANT. INSTALLER ET UTILISER DANS UN FOYER DE MACONNERIE OU PRÉFAB-
RIQUÉ. APPELER VOTRE INSPECTEUR DE BÂTIMENT OU LE DÉPARTMENT D’INCENDIE LOCAL POUR LES CODES LOCAUX ET POUR INSPECTÉE
VOTRE INSTALLATION ET FOYER.
CAUTION
ATTENTION:
CHAUD LORS DE FONCTIONNEMENT.
NE PAS TOUCHER. GARDEZ LES EN-
FANTS, VÊTEMENTS ET MEUBLES AU
LOIN.
UN CONTACT AVEC LE PEAU PEUT OC-
CASIONER DES BRULURES.BRÛLURES
CUTANÉES.
LIRE CETTE ÉTIQUETTE.
PIÈCES NÉCESSAIRES POUR INSTALLATION :5.5" (140MM) OR 6" (152MM) CONDUITS EN ACIER INOXYDABLE. ADAPTATEUR DE CONDUIT DE
FUMÉE STANDARD (171-932) OU COUDÉ (171-936) COMPONENT STANDARD : FAN ELECTRICAL RATING: VOLTS 115, 60HZ.
N'ENLEVER NI BRIQUES NI MORTIER DU FOYER LORSQUE VOUS EFFECTUEZ L'INSTALLATION DU POÊLE ENCASTRABLE. UTILISER SEULEMENT
DU BOIS DE CHAUFFAGE. NE PAS UTILISER UNE GRILLE, ÉTABLIR LE FEU DIRECTEMENT SUR LES BRIQUES DANS LE FOND DU POÊLE. OPÉREZ
AVEC LA PORTE DE NOURRITURE FERMÉE, OUVERTE POUR NOURRIR LE FEU SEULEMENT. REMPLACEZ LE VERRE SEULEMENT AVEC LE VERRE
CÉRAMIQUE (5 MM). INSPECTEZ ET NETTOYEZ VOTRE CHEMINÉE FRÉQUEMMENT. LA FRÉQUENCE D’UTILISATION ET LA TEMPÉRATURE AUX-
QUELS LE POÊLE EST UTILISÉ DE FAÇON RÉGULIÈRE PEUT AFFECTER CETTE ACCUMULATION DE CRÉOSOTE. NE PAS SURCHAUFFER.
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 1.5IN / 38MM
ABOVE AN ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR MUST
BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING
(E) 16 IN / 405MM (US), 18 IN / 457MM (CAN) TO FRONT AND (G) 8 IN / 205MM
TO SIDES FROM FUEL DOOR.
INSTALLER SUR UN ÂTRE DE MATÉRIAU NOM COMBUSTIBLE SURÉLEVÉ
(F) 1,5 POUCES / 38MM-DESSUS DU PLANCHER COMBUSTIBLE ADJACENT.
LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR LE MATÉRIAU NOM
COMBUSTIBLE QUI ÉTENDRE
(E) 16 IN / 405MM (ETATS-UNIS), 18 IN / 457 MM (CAN) EN AVANT ET (G) 8 IN /
205MM LES CÔTÉ DE LA PORTE.