INSTALLATION
38-7/16"
976mm
29"
[737mm]
NO FACING OR
FINISHING MATERIAL
IN THIS AREA
No Combustible
Materials in this Area
44-1/4"
[1
124mm]
46-11/16"
[1186mm]
3-9/16"
[91mm]
11-5/8"
[295mm]
4-1/8"
[105mm]
6" [152mm]
50-1/4"
[1276mm]
NON-COMBUSTIBLE BOARD SUPPLIED W/UNIT
J Style trim or metal
corner bead may be
used to finish edges
No Combustible
Materials in this Area
29"
[737mm]
38-7/16"
976mm
7.
Non-combustible material (ie. tile, slate, etc) may be brought up to the edge of the glass door of the unit. Minimum clearances must be adhered to, this
will assure ease of glass door removal and access to the lower panel.
NOTE:
Non-combustible fi nishing materials may be of any thickness desired.
Minimum Clearances for Finishing Materials
Trim materials
Note:
All non-combustible facing material should butt up cleanly
to the fl anges around the fi rebox opening.
Rough edges may be visible from an angle.
To maintain a clean fi nished edge - facing material edges
may be fi nished with a J-style trim or metal cornerbead (both
materials available at your local building or hardware store).
IMPORTANT:
Materials used must be NON-COMBUSTIBLE.
IMPORTANT FINISHING DETAIL NOTE:
Before placing unit into
fi
nal position - it is important to know the total
thickness / height of
fi
nished hearth (tile, carpet, etc.) The base of the
fi
replace, 4 sided faceplate or mantel should be level or higher than the
fi
nished hearth height.