28
Regency Bellavista™ B41XTCE Gas Fireplace
INSTALLATION
Pipe Length
Vertical
Termination
Cap
Storm Collar
Flashing
Ceiling Firestop
Rigid Pipe Adaptor
Pipe
Length
Pipe Length
90 Elbow
o
Astrocap
(946-523/P)
Wall Thimble
Vinyl Siding
Standoff (Optional)
Reducer
(4” x 6-5/8” venting)
43”
092 mm)
RIGID PIPE VENTING SYSTEMS
BASIC HORIZONTAL & VERTICAL TERMINATIONS
Rigid Pipe Vent Systems offer a complete line of
component parts for installation of both horizontal
and vertical installations. Many items are offered
in decorative black, as well as galvanized fi nish.
The minimum components required for a basic
Horizontal Termination are:
1 AstroCap XL Termination Cap
1 90
o
Elbow
1 Rigid
Pipe
Adaptor
1 Wall
Thimble
1 Length of rigid pipe to suit wall thickness
The minimum components required for a basic
Vertical Termination are:
1 Vertical
Termination
Cap
1 Rigid
Pipe
Adaptor
1 Lengths of pipe to adequately
penetrate
roof
1 Ceiling
Firestop
1 Flashing
1 Storm
Collar
Wall thickness is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl, furring
strips may be used, instead of a vinyl siding
standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed
into siding. Measure the wall thickness including
furring strips.
If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
The FPI AstroCap XL
TM
is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent
®
Direct Vent Pro, ICC Excel and Selkirk
Direct-Temp. AstroCap XL
TM
is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or
proprietary trademarks of Simpson Dura-Vent Co. Inc.
This product has been evaluated by Intertek for
using a Rigid Pipe Adaptor in conjunction with
Simpson DV Pro, Metal-Fab Sure-Seal, ICC
Excel and Selkirk Direct-Temp systems. Use
of these systems with the Rigid Pipe adaptor
is deemed acceptable and does not affect the
Warnock Hersey/Intertek listing of components.
WARNING:
Do not combine venting components from
different venting systems.
Exception: However, use of the the AstroCap
XL
TM
is acceptable with all systems.
Alternate Snorkel
Termination Cap
HOT
Alternate
Horizontal Termination
Caps
A
B