background image

Regency Bellavista™ B41XTCE Gas Fireplace

41

INSTALLATION

11)

 Position Log E on top of Log G - fi t Log E into the pin on Log G as 

      shown below.

12)

 With Log E in position on Log G - ensure that Log E touches the  

back corner of Log A as shown below.

13)

 Position Log B on top of Log A.  Log B fi ts into the pin in Log A.

       Ensure Log B sits upright 90 degrees with the left side of the log 

resting on the notch in Log E. See next 2 diagrams.

 

14)

  Position Log C on top of Log H.  Log C fi ts into the pin in Log H.

       as shown below. 

E

G

E

A

A

B

C

15)

 With Log C in position on Log H - assure that Log C contacts the  

back corner of Log A as shown below.

C

A

E

B

Summary of Contents for Bellavista B41XTCE-LP

Page 1: ...to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 919 162 06 07 12 Owners Installation Manual Tested by Install...

Page 2: ...e warmth and charm of a wood fireplace at the flick of a switch The Bellavista B41XTCE has been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency ...

Page 3: ...on instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wire to t...

Page 4: ...ical terminations 30 Three 3 90o Elbows Rigid Pipe 5 x 8 30 Unit Installation with Horizontal Termination 31 Unit Installation with Horizontal Termination 32 Unit installation with Vertical Termination 33 Gas Line Installation 33 Pilot Adjustment 34 High Elevation 34 886 S I T Valve Description 34 Gas Pipe Pressure Testing 34 Brick panel installation 35 Optional panel installation 36 Log set insta...

Page 5: ...Minimum input Maximum input Altitude FPI Fireplace Products International Ltd Delta BC Canada 919 163 This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 or Natural Gas and Propane Installation Code CSA B149 1 This appliance must be installed in accordance with the Standard CAN CSAZ240 MH Mobile Housing in Canada or with the ...

Page 6: ...ectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspec...

Page 7: ... 3 8 22 674 46 11 16 25 9 16 16 7 16 32 5 8 38 1 4 36 3 8 26 3 16 3 1 4 49 1 4 11 5 8 7 5 16 1 9 16 1 1 2 35 44 1 4 3 5 8 29 1 8 23 7 16 38 7 16 1185mm 974mm 46 11 16 1185mm 976mm 889mm 738mm 92mm 594mm 649mm 664mm 1251mm 38mm 1123mm 417mm 829mm 185mm 294mm 724mm 39mm 923mm 971mm ...

Page 8: ... The appliance installation must conform with local codes or in the absence of local codes with the current Canadian or National Gas Codes CAN1 B149 or ANSI Z223 1 Installation Codes 2 The appliance when installed must be electricallygroundedinaccordancewithlocal codes or in the absence of local codes with the current National Electrical Code ANSI NFPA 70 or CSA C22 1 Canadian Electrical Code 3 Se...

Page 9: ...l Clearances section d Framing FinishingRequirements Refer to Framing Finishing section e VentingRequirements Referto Venting section 2 Assemble Top Standoffs and Top Facing Support and Side Nailing Strips Refer to Unit AssemblyPriortoInstallation Section Note Mustbedonebeforeinstallingunitinto place 3 Install vent Refer to Venting sections 4 Makegasconnections Testthepilot Mustbe as per diagram R...

Page 10: ...pace to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions B41XTCE Clearance Requirements Horizontal Top 3 76mm Horizontal Side 2 51mm Horizontal Bottom 2 51mm Vertical Vent 2 51mm NOTE A16 deep non combustible hearth pad is recommended for hardwood flooring and carpet Clearance Dimension Measured From ...

Page 11: ... top of front facing are shown in the diagram on the right Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board Mantel Clearances B41XT A B C D From Top of Fireplace Opening 32 11 16 830mm 25 13 16 656mm 22 1 16 560mm 17 9 16 446mm Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace Opening 12 1 7 A...

Page 12: ...this Area 44 1 4 1124mm 46 11 16 1186mm 3 9 16 91mm 11 5 8 295mm 4 1 8 105mm 6 152mm 50 1 4 1276mm NON COMBUSTIBLE BOARD SUPPLIED W UNIT 9 Side Wall Measured from side of Fireplace Opening 7 4 Mantel leg Mantel leg Allowable mantel leg projection 3 1 1 2 NOTE The 6 x 46 11 16 supplied with the unit is secured directly above the unit as shown above All other non combustible material is supplied by ...

Page 13: ... Ceiling Top 54 1 2 1384mm S Rear Vent Vent Centerline Height Rear 28 1 2 724mm S Top Vent Vent Centerline Height Top 47 1 2 1207mm Rigid Flex T Gas Connection Height 1 1 2 38mm U Gas Connection Inset 5 127mm V Gas Connection Width 3 1 4 82mm W Non Combustible Top Height 13 1 2 343mm Important Framing height requires consideration of the hearth depth Dimension N N the thickness of the installed he...

Page 14: ... a non combustible finishing material tile slate etc the material can be installed directly onto the metal surface clean front of the unit in the area shown below 1 2 DRYWALL NON COMBUSTIBLE FACING FOR CLEAN LOOK ie painted finish SUPPLIED BY OTHERS 46 11 16 1186mm 1 2 DRYWALL DO NOT EXTEND DRYWALL ONTO METAL SURFACE OF UNIT WOOD STUD 44 1 4 1124mm 6 152mm NON COMBUSTIBLE BOARD SUPPLIED W UNIT 38 ...

Page 15: ... and access to the lower panel NOTE Non combustible finishing materials may be of any thickness desired Minimum Clearances for Finishing Materials Trim materials Note All non combustible facingmaterialshouldbuttupcleanly to the flanges around the firebox opening Rough edges may be visible from an angle To maintain a clean finished edge facing material edges may be finished with a J style trim or m...

Page 16: ...mm The top nailing strip is adjustable to 1 2 13mm 2 Bend the required four 4 nailing strips to 90º 3 Attach top nailing strip with one 1 screw located at the back of the nailing strip Adjust to required position flush or back 1 2 and tighten screw Nailing strip for Tile Finish set back 1 2 Nailing strip for Clean Finish set flush with unit Adjustable Top Nailing Strip NAILING STRIPS TOP STANDOFF ...

Page 17: ...ate Cover 1 Insulation Filling 1 Remove the door by releasing the spring hooks at the bottom and lifting the door up off the door frame 2 From inside the firebox remove the baffle plate by removing 4 screws remove top front screw first Baffle Plate 3 From the inside of the firebox remove the exhaust assembly by removing the 10 screws 5 From the outside top of the firebox remove top insulation cove...

Page 18: ... all screws are tight but do not over tighten All 4 screws must be used 13 Set vent restrictor accordingly see next page 14 From inside the firebox re install the baffle plate from step 2 11 From the outside top of the firebox install the intake collar as sembly Secure with 4 1 4 x 1 2 screws Ensure all screws are tight but do not over tighten All 4 screws must be used Intake Collar Assembly Exhau...

Page 19: ... 2 screws Ensure all screws are tight but do not over tighten See diagram 2 SET 3 THIS HOLE SETS THE VENT RESTRICTOR AT 1 1 2 SET 2 THIS HOLE SETS THE VENT RESTRICTOR AT 2 1 2 SET 1 THIS HOLE SETS THE VENT RESTRICTOR AT 3 1 2 NO VENT RESTRICTOR Factory setting Baffle Plate Diagram 3 Diagram 1 VENTING INTRODUCTION The B41XTCE uses the balanced flue technology Co Axial system The inner liner vents p...

Page 20: ...r line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located...

Page 21: ...x 58DVA CS 5DT CSS 5DRS TE 5DE45B Wall Support Band 58DVA WS 5DT WS B 5DWS N A Offset Support 58DVA ES N A from FPI 5DT OS N A N A Wall Thimble Black 58DVA WT 5DT WT 5DWT TE 5DE90 Wall Thimble Support Ceiling Support 58DVA DC N A from FPI N A N A TE 5DE90B Firestop Spacer 58DVA FS 5DT FS 5DFS N A Trim Plate Black 58DAV WFS 5DT TP 5DCP N A Description Simpson Direct Vent Pro Selkirk Direct Temp Met...

Page 22: ...Simpson Direct Vent Vent Guard Optional 946 623 P AstroCap XL Horizontal Cap 770 994 Rigid Pipe Adaptor Must use with all rigid piping 946 506 P Vent Guard Optional 946 606 Starter collar reducer 5 x 8 to 4 x 6 5 8 946 625 Vinyl Siding Standoff AstroCap XL Note When using Metal Fab Sure Seal Rigid Piping please note that the Adaptor 4DDA must be used in conjunction with FPI Rigid Pipe Adaptor 510 ...

Page 23: ... 0 6 4 8 Vertical Height Feet Rigid or Flex 47 1 2 1 2m Horizontal Feet Max 36 0 9m 2 0 6 4 8 2 0 6 4 8 Vertical Height Feet 28 1 2 0 7m Horizontal Feet Max 36 0 9m Vent Restrictor Set 1 Factory Setting No Restrictor Required VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS FLEX VENT OR RIGID PIPE 5 X 8 REAR VENTING DEFLECTOR INSTALLATION FOR REAR VENTED HORIZONTAL TERMINATIONS Rear Venting Deflec...

Page 24: ...top or rear vent Notes 1 Liner sections should be continuous without any joints or seams 2 Only Flex pipe purchased from Regency may be used for Flex installations 3 Regency Direct Vent System Flex is only approved for horizontal terminations NOTE If longer runs are required the FPI Direct Vent system Flex 946 616 includes all parts needed to install the B41XTCE with a maximum 10 run FPI Kit Lengt...

Page 25: ...ap Wall Thimble Vinyl Siding Standoff Optional Horizontal Termination A Top Vent No Vertical Rise When venting with a 90 elbow directly off the unit Flex vent or approved Rigid Vent System Max 3 ft horizontal run B Rear Vent w Horizontal Termination Max 3ft horizontal run B A HORIZONTAL TERMINATIONS RIGID PIPE 5 X 8 IMPORTANT Must use Rear Venting Deflector packaged with unit in rear vent horizont...

Page 26: ...12 Includes 1 AstroCap XL 946 623 P 1 Rigid Pipe Adaptor 770 994 1 Vinyl Siding Standoff Optional 946 625 1 Wall Thimble 58DVA WT 1 6 Galvanized Rigid Pipe 58DVA 06 1 8 1 2 Galvanized Pipe Extension 58DVA 08A 1 45º Galvanized Elbow 58DVA E45 1 90ml MillPac 948 128 28 1 2 724mm Placement of the Unit into the Corner Back Top Corner of Unit to Wall 3 Inside Corner out along the Wall 60 1 4 Across the...

Page 27: ...Set 1 VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations using one 90o two 45o elbows equal one 90o elbow Maintain clearances to combustibles as listed in Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A wall thim...

Page 28: ...nstead of a vinyl siding standoff to create a level surface to mount the vent terminal The Terminal must not be recessed into siding Measure the wall thickness including furring strips If a Vinyl Siding Standoff is required it must be usedwithvinylsiding measuretooutsidesurface of wall without siding and add 2 inches When using Rigid Vent other than Simpson Dura Vent 3 screws must be used to secur...

Page 29: ...x F 5 Min 7 Max G 6 Min 8 Max No Vent Restrictor Installed Lengths do not include elbow indicated Must use rigid pipe adaptor 770 994 One 90o elbow Two 45o elbows Option V H V V1 H H1 W i t h t h e s e options maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal Pleasenotemini mum 1 foot be tween 90o elbows is required A 0 Min 1 Max 1 Min 2...

Page 30: ...sing through a wall Maintain clearances to combustibles as listed in the Clearances section Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting to 3 1 2 opening 2 1 2 opening and to 1 1 2 opening Note Must use optional flue adapter when using Rigid Pipe Part 770 994 Maximum 35 5 ft 10 m 8 Minimum 8 2 4m Min 47 1 2 1 2m 0 2 4 6 40 ...

Page 31: ...0 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o elbows is required A 0 Min 2 Min 2 Max B 1 Min 3 Min 2 Max C 2 Min 4 Min 3 Max D 3 Min 6 Min 4 Max E 4 Min 7 Min 5 Max F 5 Min 8 Min 6 Max G 6 Min 9 Min 7 Max H 7 Min 10 Min 8 Max No Vent Restrictor Installed Lengths do not include elbow indicated Must use rigid pipe adaptor 770 ...

Page 32: ... using nails or screws through the top and side nailing strips Diagram 1 Note For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failuretodosomayresult in drafting or performance issues not covered under warranty Silicone red RTV is optional Diagram 2 Horizontal runs of vent must be s...

Page 33: ...ng sure that the tabs are on top and bottom Fasten the other thimble half to the inside wall The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls 5 Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up there are markings on the cap that show which wayis up This will position the termination cap with proper d...

Page 34: ...square hole Frame the hole as shown in Diagram 2 and install the firestop NOTE Forbestresultsandoptimumperform ance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied toeveryinnerpipeconnec tion Failure to do so may result in drafting or performance issues not covered under warranty Silicone red RTV is optional 4 Assemble the desired lengths of pipe and e...

Page 35: ... screwdriver Note Screw should be snug but do not over tighten HIGH ELEVATION This unit is approved in Canada for altitude to 4500ft CAN CGA 2 17 M91 ForNaturalGas installations above 4500 ft follow current CAN CGA B149 1 B41XTCE NG System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes 30 Max Input Rating 42 500 Btu h Min Input Rating 30 000 Btu h Supply Pressure min 5 0 w c Manifold ...

Page 36: ...rick panel in place and secure with the brick panel clip and screw removed from the firebox as shown below 6 Slide the top brick panel under the left or right side panel which ever is installed first right side panel shown here and back brick panel use care not to damage panel Left Panel Right Panel Back Panel Top Panel Back Panel Installed 7 Install the remaining side panel left or right followin...

Page 37: ... and finger marks MUST be cleaned off with a soft cloth Use an ammonia based cleaner ie glass cleaner to remove any fingerprints before applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove Not protected by product warranty 1 Prior to installation of the reflective panels remove the top panel bracket currently fitted into the baffle op...

Page 38: ...ew Location of hex head screw A B 6 Install left side panel repeat step 4 5 Slide top panel under the top of the back and right side panels as shown below Top panel bracket shown installed with Stainless Steel Panels 7 Carefully position and fit the top bracket in place by ensuring the tabs of the bracket fit into the baffle openings as shown below Push downwards to secure the bracket to the top p...

Page 39: ... following pieces A Rear Bottom Right Log B Rear Top Left Log C Right Top Cross Log D Front Log Piece E Left Top Cross Log F Center Right Log G Front Bottom Left Log H Front Bottom Right Log I Center Left Log 902 156 Lava Rocks 902 179 Vermiculite 946 669 Platinum Embers supplied w packaged manual 1 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care ...

Page 40: ... the burner as shown below 8 Slide the left side of Log G back until it touches the tab on the burner shown below 10 Slide the right side of Log H back until it touches the tab on the burner shown below I G H 9 Place Log H on the right front side of the burner in front of log F Position Log G so it fits into the pin on the burner as shown below There is a notch on the bottom of log H position the ...

Page 41: ...r of Log A as shown below 13 Position Log B on top of Log A Log B fits into the pin in Log A Ensure Log B sits upright 90 degrees with the left side of the log resting on the notch in Log E See next 2 diagrams 14 Position Log C on top of Log H Log C fits into the pin in Log H as shown below E G E A A B C 15 With Log C in position on Log H assure that Log C contacts the back corner of Log A as show...

Page 42: ...inum Embers 17 Separate platinum embers and place on the front burner on and around the lava rocks Avoid stacking platinum embers Platinum embers may be placed over burner ports IMPORTANT Do not cover burner ports with lava rocks as this will change the flame pattern Extra Lava Rocks 16 Place the lava rocks on the burner in front of the logs as shown below Be careful not to overlap the lava rock a...

Page 43: ...asing 4 Connect the Black wire to the left side terminal of the fan motor Slide the black wire and the green ground wire into grommet and push grommet into the fan assembly housing 5 Connect the Red wire onto the right side terminal of the fan motor Connect the red wire into the grommet and push grommet into the fan assembly housing BLACK RED 6 Position the fan base with the motor end towards the ...

Page 44: ...es and power cord by attaching one of the adhesive backed wire holder clips Part 910 199 onto the unit base TO REMOVE THE FAN 1 Turn the power off 2 Reverse the above instructions Maintenance The sealed bearings are lubricated there is no need to lubricate them further Extra lubricant will cause more lint and dust buildup causing the bearings to prematurely fail Regular cleaning and vacuuming of t...

Page 45: ...ptional REMOTE CONTROL UsetheRegency RemoteControlKit approved for this unit Use of other systems may void your warranty The remote control kit comes with a hand held transmitter areceiverandawallmountingplate 1 Choose a convenient location on the wall to install the receiver and the receptacle box protection from extreme heat is very important Run wires from the fireplace to that location 2 Conne...

Page 46: ... Included Feature Note 1 Proflame Flame Modulator for GTM GTMF Remote Controls are sold seperately Choice of NG or LP flame modulator to match unit fuel type See Regency Retail Price pages for complete details Note 2 FPI Proflame Remote Controls come standard with white wall mount switch cover plate 1 1 1 ...

Page 47: ...Install the heat shield to the receiver with two screws and attach to the floor of the unit with a velcro pad 12 Reverse steps 5 and 4 13 Match the remote control to the receiver see remote control instructions 14 Reverse steps 2 and 1 15 Check to ensure there are no gas leaks 4 Remove DFC digital firebox control box from the floor of the unit 5 Disconnect wire harness ground wire and spark wire f...

Page 48: ... lo knob if installed by removing 2 screws as shown below 8 Plug in receiver DC supply wire as shown below 5 Disconnect wire harness ground wire and spark wire from DFC DFC 4 Remove DFC digital firebox control box from the floor of the unit 1 Shut off the gas supply and disconnect all power to the unit 2 Remove the louvers bay door or faceplate if installed 3 Disconnect battery pack located on the...

Page 49: ... pad also peel off paper on back side of wire clip and place wires conveniently in appliance 16 Bundle all wires together and clip with supplied wire clip as shown below 18 Match the remote control to the receiver see remote control instructions 19 Reverse steps 2 and 1 20 Check to ensure there are no gas leaks Heat shield 15 Install 4 AA batteries into the receiver 13 Plug the stepper motor into ...

Page 50: ...he floor of the unit as shown below and discard 7 Connect the TPTH and TH wires green to green and white to white as shown below TPTH DFC TH 4 Identify wires in the GTM GTMF remote wiring harness see wiring diagram 5 Remove DFC digital firebox control box from the floor of the unit 9 Remove the hi lo knob by removing 2 screws as shown below 8 Plug in receiver DC supply wire as shown below 10 Insta...

Page 51: ...h wires from step 5 14 Reinstall the DFC box onto the velcro pad on the floor of the unit 15 Install the heat shield to the receiver with two screws and attach to the floor of the unit with a velcro pad 18 Plug fan control module into recepticle located on the left hand side of the unit 19 Match the remote control to the receiver see remote control instructions 20 Reverse steps 2 and 1 21 Check to...

Page 52: ...to operate However a 120V A C power supply is needed for the fan blower operation Do not cut the ground terminal off under any circumstances NOTE Even if the fan is not purchased with the unit it is still a good idea to bring power to the receptacle box provided with the unit in case the fan is installed at a later date Lockwasher Fan ground wire Nut 8 Ground Lug mobile home approved Star washer G...

Page 53: ...ME REMOTE SERIES 946 690 GT Remote System 946 691 GTM Remote System 946 692 GTMF Remote Mustalsoordera946 693 NGor946 694modulator if using the noted remote controls SureFire Switch SureFire Switch Note 4 AA batteries must be installed to operate the burner switch Do not use a 9 volt battery IMPORTANT If the optional remote control is used the AA batteries normally installed into the battery holde...

Page 54: ...n The neutral wider slot of the polarized receptacle should be at the top A wall mounted switch should be installed to turn the accent lighting on off See wiring diagram in the instruction manual Diagram 1 Remove the left and right screws Diagram 2 Slide burner assembly to the right and then remove 8 Remove the 2 screws securing the rear log tray and lift out Diagram 3 Diagram 3 7 Slide the burner...

Page 55: ... diffusers on to the base tray 16 Secure diffusers onto base tray from the backside of the tray with 2 screws 17 Reinstall base tray with light diffusers use caution when installing do not damage the bulb 18 Install amber glass on to light diffusers Note Glass is longer than diffuser for ease of removal 19 Reverse steps 9 1 NOTE The ground wire will need to be pulled back out of the protective cas...

Page 56: ...LLATION 1 Hook mesh guard frame over top of flush glass door frame as shown in Diagram 1 Push bottom part of mesh frame over flush glass door frame until tabs snaps into place 2 Install mesh guard and flush glass together following flush glass door installation instructions ...

Page 57: ...e Diagram 3 Diagram 2 The standard flush door comes with a black frame To install the frame simply hook the top door flange onto the top of the unit and swing the door towards the unit see Diagram 1 Be careful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit see Diagram 2 Diagram 1 To remove the flush d...

Page 58: ...room for a couple of hours The glass panel may require cleaning after the unit has cooled down DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT Note When the glass is cold and the appliance is lit it may cause condensation and fog the glass This condensation is normal and will disappearinafewminutesastheglass heats up DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE OPERATING INSTRUCTIO...

Page 59: ...alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des do...

Page 60: ...cy dealer only Replacement glass Part 940 362 P is shipped already installed into the door frame Reinstall as per Glass Door Installation in the Glass Door Removal section MAINTENANCE INSTRUCTIONS 1 Alwaysturnoffthegasvalvebeforecleaning For relighting refer to lighting instructions Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs ...

Page 61: ...ram 1 Remove the left and right screws Diagram 2 Slide burner assembly to the right and then remove 8 Remove the 2 screws securing the rear log tray and lift out Diagram 3 Diagram 3 7 Slide the burner assembly to the right to release it from the orifice then lift it out 9 Remove the 2 screws securing the base tray lift base tray up and out Diagram 4a and 4b Diagram 4a Diagram 4b 10 Replace the bul...

Page 62: ...Diagram 4a Diagram 4b Diagram 3 Diagram 7 INSTALLING VALVE 1 Placenewvalvetrayandgasketintoposition 2 Reinstall the 14 hold down screws 3 Connect the EV1 EV2 and ground wires to the appropriate connections on the valve 4 Reinstall the rear log tray 5 Install burner grate assembly 6 Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector Do not use open fl...

Page 63: ...ssembly 19 910 215 P Fan Motor 120 Volts 432 966 Fan Switch Assy 120 Volts 20 910 813 Power Cord 120 Volts Part Description 21 910 330 Fan Speed Control 22 904 586 Knob Speed Control 23 910 142 Thermodisc Fan Auto ON OFF 24 946 000 Round Duct Adaptor 25 910 367 Box Plastic Switch Receptacle 26 910 412 Fan Speed Controller 27 910 417 Knob White 28 910 366 Switch Cover Plate White 29 946 006 Grill P...

Page 64: ...6 911 004 Valve NG SIT 886 911 005 Valve LP SIT 886 7 506 072 Valve Shield 8 Valve Mounting 9 506 055 Valve Tray Plate 10 506 075 Air Deflector 11 380 013 Pilot Holder Extruded 12 911 006 Pilot Assembly NG 911 007 Pilot Assembly LP Flame Sensor Igniter Part Description 904 660 Orifice 30 NG 904 431 Orifice 49 LP 506 574 E P Valve Assembly NG 506 576 E P Valve Assembly LP 506 003 Valve Assembly Gas...

Page 65: ...Regency Bellavista B41XTCE Gas Fireplace 65 NOTES ...

Page 66: ...66 Regency Bellavista B41XTCE Gas Fireplace NOTES ...

Page 67: ...gent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the re...

Page 68: ... register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and spe cial offers on related products 7 Ɠ Ɠ 2 4 3 3F 3F 3F J HJ HJ HJ H U TU TU TUFS FS FS Z ƔZ ZPV PVS SƔ8 8B 8B 8BSS SS SSBO BO BOUZ UZ UZ B B ƔB E OE OE OE C C C ƔCF F FƔBV BVU UP UPNB NBUJ UJ U...