I1150 Regency Wood Insert
|
15
installation
Installer:
Please record unit serial number here before installing blower.
Serial No.______________________________
919-719
09.22.16
FAN OPERATION
The fan is controlled by a rheostat which allows control of the heat
output.
The fan will turn on as the stove has come up to operating temperature.
It will also shut the fan system off after the fire has gone out and the
unit cooled to below a useful heat output range.
If the fan cycles on and off continuously the thermo switch sensor is
not making contact with the stove body. Remove the fan, bend the
bracket closer to the stove and re-install the fan.
The fan is to be operated in the <LOW> position when burning in the
LOW - MED LOW heat output setting and on <HIGH> when burning
in the MED-HIGH settings.
Wire98gr.eps
updated Jan. 27/00
updated: Aug. 09/05
capitalized the word Nut
Lockwasher
Ground wire
from power cord
Ground wire
from fan
#8 Groun
Lug
d
Star washer
Nut
Nut
Star washer
Grounding
Lug Detail
CAUTION: Label all wires prior to disconnec-
tion when servicing controls. Wiring errors
can cause improper and dangerous operation.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged
(grounding) plug for your protection against shock
hazard and should be plugged directly into a prop-
erly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug.
Wiring Diagram
I1500
FAN
BLACK
ON
RHEOSTAT
GREEN
___l_
-==-
THERMODISC
BLACK
GRND
Fan assembly for use only with the room heater marked to indicate such use.
tooltip
Thermo Switch
Sensor
Your fan should only be installed once the unit is in place in order to
prevent any damage to the fan.
1)
Align the fan support with the offset clip on the bottom of the
ashlip.
2)
Slide the supports into the clips. The tension holding the clips
in place may be adjusted by increasing or decreasing the offset
spacing of the clips.
3)
Ensure that the power cord is not in contact with any hot stove
surfaces.
WARNING: FAN ASSEMBLY MUST BE DISCONNECTED FROM
THE SOURCE OF ELECTRICAL SUPPLY BEFORE
ATTEMPTING THE INSTALLATION.
FAN INSTALLATION
(120V FAN)
Fan / Blower
The fan should only be installed once the unit is in place in order to prevent any damage to the fan.