16
|
I1150 Regency Wood Insert
installation
Brick Installation
Firebrick is included to extend the life of your stove and radiate heat more evenly. Check to see that all firebricks are in their correct positions and have not
become misaligned during shipping. Install all firebricks (if bricks were removed at install) per the Diagram below and place in their correct positions.
Do not use a grate.
LyTherm sheet
Order of firebrick install:
a) Rear Firebrick
b) Firebox floor - install brick over LyTherm Sheet
c) Right and left side Firebricks
Fire bricks
#
Size
1
4-1/4" x 7"
2
4-1/2" x 7"
3
9" x 4-1/2"
4
9" x 2"
5
3-1/2" x 4-1/2"
6
4-1/4" x 8"
7
3-1/2" x 2-1/4"
1
4
6
5
3
7
2
ITEM
NO.
PART NUMBER QTY.
DESCRIPTION
7
RD-14287
2
3.500 x2.2500 BRICK
6
RD-14286
2
4.250 x 8.000 x 30 DEG BRICK
5
802-147
1
3.500 x 4.500 BRICK
4
802-152
2
2.000 x 9.000 BRICK
3
902-111
3
9.000 x 4.500 STANDARD BRICK
2
RD-14289
2
4.500 x 7.000 BRICK
1
RD-14288
2
4.250 x 7.000 BRICK