I1150 Regency Wood Insert
|
27
maintenance
Annual Maintenance
Completely clean out entire unit
Annually
Inspect air tube and bricks
Replace any damaged parts.
Adjust door catch assembly
If unable to obtain a tight seal on the door - replace door gasket seal.
Readjust door catch after new gasket installed.
Inspect condition and seal of:
Glass Gasket
Door Gasket
Perform paper test - replace gasket if required
Paper Test
Test the seal on the loading door with a paper bill.
Place a paper bill in the gasket area of the door on a cold stove.
Close the door.
Try to remove the paper by pulling.
The paper should not pull out easily, if it does, try adjusting the door latch, if that
doesn't solve the problem replace the door gasket.
Check and lubricate door hinge + latch
Use only high temperature anti seize lube. (ie. never seize)
Check glass for cracks
Replace if required.
Clean blower motor
Disconnect power supply.
Remove and clean blower.
*DO NOT LUBRICATE*
Inspect and clean chimney
Annual professional chimney cleaning recommended.
NOTE:
Chimney Cleaning
When cleaning the chimney system the air tubes, baffles should be removed for ease of cleaning. See manual for details on removal.
We highly recommend that the chimney cleaning be done by a professional as they will have the necessary tools such as a proper sized
brush and special vacuum cleaner designed to deal with fine particles.