City Series ACB60E
|
25
installer's information
Heatwave Duct System - Op-
tional Kit
The
HeatWave
Air Duct Kit increases the
effectiveness of your fireplace by dispersing warm
air from the fireplace to remote locations in the same
room or other rooms in your home.
Up to two kits may be installed on the fireplace.
Please Note:
One adaptor kit #946-766 must be
used with each 946-591 and 946-596.
The
HeatWave
Duct Kit has different clearance
and framing requirements, check the
HeatWave
manual for details.
Installation Checklist
1. Locate appliance. Refer to the following sections:
a) Locating Your Fireplace
b) Clearances
c) Combustible Mantel Clearances
d) Framing & Finishing
e) Venting. See the "Venting Introduction" to
"Venting Arrangements" sections.
2. Assemble Standoffs. Refer to the "Unit Assem-
bly Prior to Installation" section. (NOTE: must
be done before installing unit into fireplace.)
3. Install vent. See the "Horizontal Installations"
to "Installation Procedures" sections.
4. Install 4 AA batteries into receiver battery
box. Hook receiver to wiring marked receiver,
this will enable operation of the appliance
manually when position in "ON" position.
Note: The wire harness (marked receiver) is
located near the gas valve and will need to be
routed to the exterior of the fireplace from either
the left or right hand side of the appliance prior
finishing.
5. Bring 120 volt power to appliance and 120 volt
from the power vent cap to the appliance.
6. Make gas connections. Test the pilot. Must be as
per diagram. Refer to the "Gas Line Installation"
& "Pilot Adjustment" sections.
7. Install standard and optional features. Refer
to the following sections where applicable:
a. Barrier Safety Glass
b. Firebox (inner) glass
c. Log Set
d. Fireglass
e. Ceramic stones or other approved media
f. Painted or enamel panels (panels required)
g. Corner Kit
h. Optional Framing Kit
i. Heatwave Kit
j. Heatwave kit adaptor
8. Plug 3 prong plug for the lights into the
receptacle. The 3 prong plug will be located
near the gas valve on the appliance.
9. Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to customer.
General Safety Information
1. The appliance installation must conform with
local codes or, in the absence of local codes,
with the current Installation and Building Codes.
2. See general construction and assembly
instructions. The appliance and vent should be
enclosed.
3. This appliance must be connected to the
specified vent and termination cap to the outside
of the building envelope. Never vent to another
room or inside a building. Make sure that the
vent is fitted as per Venting instructions.
4. Inspect the venting system annually for blockage
and any signs of deterioration.
5. Venting terminals shall not be recessed into a
wall or siding.
6. Any safety glass removed for servicing must
be replaced prior to operating the appliance.
7. To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the fireplace.
8. Wear gloves and safety glasses for protection
while doing required maintenance.
9. Be aware of electrical wiring locations in walls
and ceilings when cutting holes for termination.
10. Under no circumstances should this appliance
be modified. Parts that have to be removed for
servicing should be replaced prior to operating
this appliance.
11. Installation and any repairs to this appliance
should be done by a qualified service person.
A professional service person should be called
to inspect this appliance annually. Make it a
practice to have all of your gas appliances
checked annually.
12. Do not slam shut or strike the glass door.
13. Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be used in
this appliance.
14. The appliance area must be kept clear and
free of combustible materials, (gases and other
flammable vapours and liquids).
15. When installed, the appliance must be
electrically grounded in accordance with local
codes.
This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label 41.1 MJ/h NG,
38 MJ/h Propane and 34 MJ/h ULPG after
burning appliance for 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that causes
sooting or carboning that results in damage is not
the responsibility of the manufacturer.