48
|
City Series ACB60E
installation
CHASE VENTING
A minimum
1161 cm
2
opening in the enclosure is required to maintain safe operating
temperatures. This can be achieved in a number of ways
,
including the examples shown below.
Warning: DO NOT cover or place objects in front of the air outlet(s).
Regency Chase Vent
Dimensions:
76 mm x 1524 mm
(
1161 cm
2
)
Custom chase vent
Example dimensions:
63.5 mm
x
1829 mm
(
1161 cm
2
)
Reveal at the chase top
Example dimensions:
44 mm
x
2845 mm
(
1264 cm
2
)
Venting into an adjacent room
Minimum 288in
2
Note: An adjacent room cannot be a garage/closed in carport.
Chase Venting
Note: The enclosure opening cannot be any lower than 0-51 mm from the top of the enclosure for all installations.
Minimum height of enclosure from base of appliance is 2063 mm.