GUIDELINES FOR INSTALLING A TV/ARTWORK ABOVE THE UNIT
Note: All wiring should stay free and clear of the vent system to avoid damage
due to heat. We recommend using a metal receptacle box and BX cable (120
volt wire protected by metal sheathing) if located directly in front of the vent
system. Ensure wiring is secured without any sag.
ZERO CLEARANCE TO TV:
While most consumers prefer to centrally locate
a wall mounted TV, the “Cool-Touch Wall Technology” means that the bottom
edge of the TV can be installed flush with the bottom edge of the ventilated
fireplace chase opening.
The TV may be recessed into a wall as shown below.
This can only recess into the chase opening a maximum of 3-1/2 inches
and must be a minimum of 12 inches from the fireplace lip to the first stud.
To achieve a maximum of 3-1/2" recess, the wall must be of a maximum
of 2" as shown.
TV RECESSED INTO WALL
The TV cannot be
any lower than this
finishing lip
3.5”
MAX
3.5”
MAX
2.0”
Ve
rtical 2x4 12.0
” MIN
Ho
riz
on
tal 2x4
15.5
” MIN
15.5”
3.5”
2”
3.5”
MAX
12.0”
20.0”
16.5”