Regency Freestanding Woodstove

5

This is a copy of the label that accompanies 
each Regency Large Freestanding Woodstove 
(F3100L). 

 We have printed a copy of the contents here 
for your review.

SAFETY LABEL

NOTE:

 Regency units are constantly being 

improved. Check the label on the unit and if 
there is a difference, the label on the unit is the 
correct one.

UNITED STATES  ENVIRONMENTAL 

PROTECTION  AGENCY

F3100L  WITH 

AIRMATE SHIELD

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

F3100L 

WITH AIRMATE SHIELD

RESIDENTIAL INSTALLATION USING

 SINGLE WALL  CONNECTOR

SIDEWALL 

A 460 mm / 18 in  D 810 mm / 32  in

BACKWALL  B 305 mm / 12 in  E 470 mm / 18.5in
CORNER 

C  215  mm / 8.5 in  F  560  mm / 22  in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  MOBILE HOME 

SIDEWALL 

A  460  mm / 18 in 

D  810  mm / 32 in

BACKWALL  B  240  mm / 9.5 in  E  405  mm / 16 in
CORNER 

C 255 mm / 10 in  F 595 mm / 23.5in 

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

SIDEWALL 

A  405  mm / 16  in 

D  760  mm / 30 in

BACKWALL  B  240  mm / 9.5 in  E  405  mm / 16 in
CORNER 

C  215  mm / 8.5 in  F  560  mm / 22 in

SIDEWALL 

G 405  mm / 16 in 

I  760  mm / 30 in

BACKWALL  H  240  mm / 9.5 in  J  405  mm / 16 in

MEASURE 

 

 

 

 

 

   FLUE

FROM  

HEATER 

 

CENTER-LINE

COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA:  LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH  LISTED CHIMNEY SYSTEM: 
SECURITY MODEL S2100, ICC EXCEL 2100.
IN USA: 

 LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA 

VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL.  CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS 
SECURITY MODEL S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR 
METAL-FAB TEMP/GUARD, AMERI-TEC HS,  ICC EXCEL 2100 .  USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.

MINIMUM CLEARANCE BETWEEN HORIZONTAL CHIMNEY CONNECTOR AND COMBUSTIBLE MATERIALS - 460 MM (18 IN.). CLEARANCE MAY BE 
REDUCED BY THE USE OF LISTED PIPE SHIELDS, WALL PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS.  
COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND 
SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL. 

FOR USE WITH SOLID WOOD FUEL ONLY.  USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION.  DO NOT OB-
STRUCT COMBUSTION AIR OPENINGS.  OPERATE ONLY WITH FIREBRICKS IN PLACE.  OPERATE ONLY WITH DOOR CLOSED - OPEN FEED DOOR TO 
FEED FIRE ONLY.  DO NOT USE GRATE OR ELEVATE FIRE.  BUILD WOOD FIRE DIRECTLY ON HEARTH.  DO NOT OVERFIRE - IF HEATER OR CHIMNEY 
CONNECTOR GLOWS YOU ARE OVERFIRING.  INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY.  UNDER CERTAIN CONDITIONS OF 
USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY.  KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER.  REPLACE 
GLASS ONLY WITH NEOCERAM GLASS. 
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS, SCREEN DOOR

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - ALCOVE

HOT WHILE IN OPERATION DO NOT TOUCH.  KEEP CHILDREN,

CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.

DO NOT REMOVE THIS LABEL

102

CERTIFIED TO COMPLY WITH  JULY 1990, 

PARTICULATE EMISSION STANDARDS.

 JAN 

  FEB 

 MAR 

 APR 

 MA

Y

 

 JUN 

 JUL

 

 AUG  

 SEPT 

 OCT 

 NOV 

 DEC

CAUTION

DA

TE OF MANUF

ACTURE

908-351a 

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPER-
ATING INSTRUCTIONS.  CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND 
INSTALLATION INSPECTION IN YOUR AREA.  USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK 
OR 25 MSG BLUED STEEL CONNECTOR WITH LISTED FACTORY-BUILT CHIMNEY SUITABLE FOR USE 
WITH SOLID FUELS OR MASONRY CHIMNEY.  
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED 
FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.  DO NOT PASS CHIMNEY 
CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING.  DO NOT CONNECT THIS UNIT TO A CHIM-
NEY FLUE SERVING ANOTHER APPLIANCE.

F3100L WITHOUT 
AIRMATE SHIELD

F3100L  

WITHOUT AIRMATE SHIELD

MEASURE 

 

 

 

 

 

   FLUE

FROM  

HEATER 

 

CENTER-LINE

RESIDENTIAL INSTALLATION USING

 SINGLE WALL  CONNECTOR

SIDEWALL 

A 510 mm / 20  in  D 860 mm / 34  in

BACKWALL  B 355 mm / 14  in  E 520 mm / 20.5 in
CORNER 

C  265  mm / 10.5in  F  610  mm / 24  in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  MOBILE HOME 

SIDEWALL 

A  510  mm / 20 in 

D  860   mm / 34  in

BACKWALL  B  305  mm / 12 in 

E  470  mm / 18.5 in

CORNER 

C  255  mm / 10 in 

F  595  mm / 23.5 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

SIDEWALL 

A  510  mm / 20 in 

D  860  mm / 34  in

BACKWALL  B  305  mm / 12 in 

E  470  mm / 18.5 in

CORNER 

C  215  mm / 8.5 in  F  560  mm / 22  in

ALCOVE INSTALLATION  

REQUIRES  AIRMATE SHIELD

FLOOR 

PROTECTION*

405 mm / 16 in

150 mm / 6 in

150 mm / 6 in

LISTED SPACE HEATER, SOLID FUEL TYPE,  SUITABLE FOR 
MOBILE HOME INSTALLATION

 

MODEL:  REGENCY  LARGE  FREESTANDING STOVE - 

F3100L

MANUFACTURED BY: 

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.

 

6988 VENTURE ST.

 

DELTA, BC  V4G 1H4

       MADE 

IN 

CANADA

TESTED TO: ULC S627-00 / UL 1482-1998 / UL 737-2000 

REPORT NO.6623 (MAY 93)

102

  

 

* In Canada, fl oor protection must 
extend 18" to the front and 8" to 
each side of the stove.

2008

2009

2010

COPY OF SAFETY LABEL FOR F3100L

Summary of Contents for Classic F1100

Page 1: ...4 908 288c MODELS F1100S F3100L Freestanding Woodstoves 11 12 09 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Page 2: ...ALER in your area Keep those REGENCY FIRES burning SAFETY NOTES If this woodstove is not properly installed a house fire may result For your safety follow the installation instructions contact local building or fire officials about restrictions and installation inspection requirements in your area This appliance needs fresh air for safe operation and must be installed with adequate combustion air ...

Page 3: ...nector Pass throughs 13 Recommended Heights For Woodstove Flue 14 Mobile Home Installation 14 Listed Components For Mobile Home Installation 15 Brick Flue Baffle Secondary Air Tube Installation 16 Brick Installation 17 Door Handle 17 Glass Installation 17 Optional Accessories 17 Screen Door 17 OPERATING INSTRUCTIONS Operating Instructions 19 First Fire 19 Draft Control 19 Ash Disposal 20 Safety Gu...

Page 4: ...FROM HEATER REPLACE GLASS ONLY WITH NEOCERAM GLASS COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL OPTIONAL COMPONENT FAN ELECTRICAL RATING VOLTS 115 60 HZ 2 AMPS SCREEN DOOR MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS F1100S WITH AIRMATE SHIELD F1100S WITHOUT AIRMA...

Page 5: ...H DOOR CLOSED OPEN FEED DOOR TO FEED FIRE ONLY DO NOT USE GRATE OR ELEVATE FIRE BUILD WOOD FIRE DIRECTLY ON HEARTH DO NOT OVERFIRE IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER REPLACE GLASS ONLY WITH NEOCER...

Page 6: ...Regency Freestanding Woodstove 6 UNIT DIMENSIONS F1100S Dimensions F3100L Dimensions 25 1 4 641mm DIMENSIONS ...

Page 7: ...is unit to a chimney serving another appliance unless approved by your local building authority 12 A chimney connector cannot pass through an attic or roof space closet or similar concealed space or a floor ceiling wall or partition of combustible construction In Canada if pas sage through a wall or partition of combustible construction is desired the installation shall conform to CAN CSA B365 Ins...

Page 8: ...2 16 23 5 with Rear Deflector 20 12 10 34 18 5 23 5 NOTE Be aware that local Codes and Regulations may override some clearances listed in this manual Check with your local inspector Residential Installation C Vent Single Wall Unit From Unit From Corner From Flue Center line A B C D E F Small F1100S with Airmate 13 11 8 25 17 5 20 with Rear Deflector 15 10 5 11 27 17 23 Large F3100L with Airmate 18...

Page 9: ...efined by local codes extend ing beneath the heater and a minimum of 6 from each side and minimum 16 from the front face of the stove and minimum 6 or the rear clearance to combustibles whichever is smaller from the rear of the stove NOTE In Canada floor protection must extend 18 to the front and 8 to each side of the stove From From Flue Min Min Hearth Unit Unit Center line Width to Rear Wall G H...

Page 10: ...6 Therearheatdeflectorissuppliedwiththestove andmustbeinstalledunlesstheoptionalairmate hasbeenselected Itstopstheheatradiatedfrom thefluecollarfromoverheatingtherearwall The rear heat deflector is installed on top of the rear heat shield as shown in Diagram 4 Pedestal Assembly Small 850 115 Large 850 315 1 For easier assembly tip the stove on its back onto a soft surface to prevent scratch ing Hi...

Page 11: ...decrease problems such as difficult start ups back smokingwhendoorisopen and dirty glass It might be sufficient to initiallytrywiththeminimumrequired height and then if problems do arise add additional height at a later date 4 Slide the roof flashing over your chimney and seal the flashing to the roof with roofing compound Secure the flashing to your roof with nails or screws 5 Place the storm col...

Page 12: ...re no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the stove through a combustible wall to a masonry chimney special methods are needed Ensure that an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure MASONRY FIREPLACE There...

Page 13: ...rick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a minimum 24 gage 024 61 mm 6 152 4 mm metal chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through Thereshallbeaminimum6 152 4 mmsepara...

Page 14: ... Example b One 90 deg elbow 2 ft 2 ft of horizontal run 4 ft one T 3 ft Total Addition at sea level 9 ft Recommended Flue Height Elevation Example a Example b 0 18 21 1000 18 72 21 84 2000 19 44 22 68 5000 21 60 25 20 8000 23 76 27 72 Once you have properly marked the position of your unit and the floor protection as outlined in the Residential Installation items 1 through 8 a supply of fresh air ...

Page 15: ...ll and Large Freestanding pedestal units are approved for installation in a Mobile Home if one of the following pipe systems is used U S Installation METALBESTOS SSII Qty Part Description 1 6DS VK Connector Kit 1 6TMH Shield Support 1 6TAF 6 Flashing 1 6T 36 Chimney Length 1 6T 18 Chimney Length 1 6T CT Rain Cap PRO JET 3103 Qty Part Description 1 PV06 TK Connector 1 CSB Shield Support 1 RRS Radia...

Page 16: ...y occur if the bafflesareimproperlypositioned Checkthe position of the brick baffles on a regular basis as they can be dislodged if too much fuel is forced into the firebox The Large Stoves F3100L and S3100L are shipped with one of the secondary air tubes loose inside the firebox It needs to be installed after the brick baffle are installed Follow the directions below Small Stove F1100S 1 If the t...

Page 17: ...rebox and replace all the bricks except for the brick over the ash plug See brick diagrams 5 Place the ash plug tool beside the lid then slide the ash drawer inside Refer to the Ash Drawer Operating section Freestanding Small F1100 Pedestal Ash Drawer Kit 850 100 1 Remove the bricks from the floor of the firebox 2 If using ashdrawer discard cover plate 3 Remove the ash dump cover plates one inside...

Page 18: ... Red Black Fan Thermodisc normally open 120V AC 60 Hz Blower Fan Wiring Diagram CAUTION Label all wires prior to disconnection whenservicingcontrols Wiringerrorscancause improper and dangerous operation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grou...

Page 19: ...nent dam age to the unit and void your warranty FIRST FIRE When your installation is completed and in spected you are ready for your first fire 1 Open control fully 2 Open firebox door and build a small fire using paper and dry kindling Secure door on the firebox and wait a few minutes for a 13 Allfuelburningappliancesconsumeoxygen during operation It is important that you supply a source of fresh...

Page 20: ...eep the door closed during operation and maintain all seals in good condition 3 Do not burn any quantities of paper gar bage and never burn flammable fluids such as gasoline naptha or engine oil in your stove 4 Ifyouhavesmokedetectors preventsmoke spillage as this may set off a false alarm 5 Do not overfire heater If the chimney con nector flue baffle or the stove top begin to glow youareoverfirin...

Page 21: ...losertothedoorframe causingatighter seal Removeandreplacethenuts washerand spacer as shown GLASS MAINTENANCE Your Regency stove is supplied with 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce In the event that you break your glass by impact purchase your replacement from an authorized Regencydealeronly andfollowourstep by step instructions for replacem...

Page 22: ...r Gasket Repair Kit 17 846 918 Hinge Cap Gold 2 set 948 079 Hinge Cap Nickel each 19 948 101 Spring Handle Large Gold 948 135 Spring Handle Large Nickel 20 948 102 Spring Handle Small Gold 948 136 Spring Handle Small Nickel F1100 F3100 STOVE MAIN ASSEMBLY Part Description Part Description 846 515 Complete Fan Blower Assy 120 V 25 910 684 Power Cord 120 V 27 910 142 Thermodisc Fan AutoON OFF 28 910...

Page 23: ...Plug Tool Handle 56 850 121 Bottom Shield Small 850 321 Bottom Shield Large 57 Blanking Plate Btm Shield 850 101 Ashdrawer Kit Btm Shield 55 Ashdrawer Bottom Shield 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle 140 850 126 Legs Cast Black 850 127 Legs Cast Gold 850 128 Legs Cast Brush Nickel 948 216 Regency Logo Gold 948 223 Regency Logo Nickel Not available as a replacement part PEDESTAL BO...

Page 24: ...Partial 1 1 4 x 4 1 2 x 3 1 2 76 Brick Partial 1 1 4 x 2 x 9 77 Brick Partial 1 1 4 x 3 1 4 x 9 78 Brick Partial 1 1 4 x 4 1 2 x 3 1 4 79 Brick Partial 1 1 4 x 4 1 2 x 2 1 4 80 Brick Partial 1 1 4 x 6 1 2 x 2 1 4 81 Brick Partial 1 1 4 x 1 1 4 x 9 82 Brick Partial 1 1 4 x 3 1 8 x 4 1 2 83 Brick Partial 1 1 4 x 3 3 8 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Partial 1 1 4 x 4 1 4 x 8 Not avai...

Page 25: ...Regency Freestanding Woodstove 25 NOTES ...

Page 26: ...Regency Freestanding Woodstove 26 NOTES ...

Page 27: ...costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type of unit problem and part or parts ...

Page 28: ...__________________________________________________ Printed in Canada Regency fireplace products are designed with reliability and simplicity in mind In ad dition ourinternalQualityAssuranceTeam carefully inspects each unit thoroughly before it leaves our door Fireplace Products International Ltd is pleased to extend this Limited Lifetime Warranty to the original pur chaser of a Regency Product See...

Reviews: