20
|
F2450M Regency Freestanding Woodstove
installation
Brick Installation
Firebrick is included to extend the life of your stove and radiate heat more evenly. Check to see that all firebricks are in their correct positions and have not
become misaligned during shipping. Install all firebricks (if bricks were removed at install) per the diagram below and place in their correct positions.
Do not use a grate.
NOTE:
The "AD" brick in the drawings above is the brick covering the Ash Dump hole that is used when the Ash Drawer Kit is installed (refer
to the Listed Components for Mobile Home Installation section).
LyTherm sheet
Order of firebrick install:
a) Rear Firebrick
b) Firebox floor - install brick over LyTherm Sheet
c) Right and left side Firebricks
70
AD
70
70
70
74
72
72
76
70)
Brick - Regular Full Size: 1-1/4" x 4-1/2" x 9"
72)
Brick Partial: 1-1/4" x 2" x 4-1/2"
74)
Brick Partial: 1-1/4" x 4-1/2" x 3-1/2"
76)
Brick Partial: 1-1/4" x 2" x 9"