10 | I1205
10 |
installation
1)
Positive Flue
Connection
with Cleanout
2)
Direct Flue
Connection
with Cleanout
3a)
Full Flue Liner
(No Cleanout
Required)
Note: A clean-out door is sometimes
required, by your inspector, to be
installed when either the Positive flue
connection or Direct flue connection
method is used.
The use of one of the connection methods listed
on this page not only increases the safety of your
insert by directing the hot gases up the flue, but
will also help increase the unit's efficiency and
decrease creosote deposits in the chimney.
When a connected flue or liner is in use, the
insert is able to “breathe” better by allowing a
greater draft to be created. The greater draft can
decrease problems such as, difficult start-ups,
smoking out the door, and dirty glass.
INSTALLATION INTO A
FACTORY BUILT
FIREPLACE
1)
When installed in a factory built fireplace, a
full stainless steel rigid or flexible flue liner
is mandatory, for both safety and perform-
ance purposes. When a flue or liner is in
use, the insert is able to breathe better by
allowing a greater draft to be created. The
greater draft can decrease problems such
as, difficult start-ups, smoking out the door,
and dirty glass.
2)
In order to position the flue liner, the exist
-
ing rain cap must be removed from your
chimney system. In most cases the flue
damper should also be removed to allow
passage of the liner.
3)
In most cases opening the existing spark
screens fully should give enough room for
the insert installation. If it does not, remove
and store.
When referencing installation or connec-
tion to masonry fireplaces or chimneys, the
masonry construction must or shall be code
complying.
INSTALLATION INTO A
MASONRY FIREPLACE
The insert must be installed as per the require-
ments of your local inspection authority. Three
methods of flue connection are acceptable in
most areas, these include:
1)
Positive flue connection, where a large
blocking plate and a short connector pipe
is used.
2)
Direct flue connection, where a smaller
blocking plate and a connector pipe to the
first flue liner tile is used.
3)
Full flue liner, where a stainless steel rigid
or flexible liner pipe is routed from the insert
outlet collar to the top of the chimney.
Regency highly recommends the use of a full
liner as the safest installation and provides the
most optimum performance. Your retailer should
be able to help you decide which system would
be the best for your application.
In Canada this fireplace insert must be
installed with a continuous chimney liner
of 5.5" (140mm) or 6" (152mm) diameter
extending from the fireplace insert to the
top of the chimney. The chimney liner must
conform to the Class 3 requirements of
CAN/ULC-S635 or CAN/ULC-S640, Stand-
ard for Lining Systems for New Masonry
Chimneys.
4)
If the floor of your fireplace is below the
level of the fireplace opening, adjust the
insert's levelling bolts to accommodate the
difference. When additional shimming is
required, use non-combustible masonry or
steel shims.
5)
Measure approximately the alignment of the
flue liner with the position of the smoke outlet
hole on the insert to check for possible offset.
If an offset is required, use the appropriate
offset adaptor in your installation.
6)
Once the above items have been checked,
slide your insert into position after first po
-
sitioning and securing the flue liner to the
offset adaptor.
Attach the rod to the adaptor and slide the
adaptor onto the unit as the unit is slid into
position. Ensure a positive connection.
Secure the adaptor to the unit by using 2
bolts, flat washers, lock washers and one
screw in the front.
Re-install raincap at completion of installa-
tion.
Summary of Contents for Classic I1205M
Page 25: ...Encastrable au bois Regency I1200 25 notes ...
Page 30: ...30 Encastrable au bois Regency I1200 garantie ...
Page 31: ...Encastrable au bois Regency I1200 31 ...
Page 60: ...28 I1205 28 warranty ...
Page 61: ...I1205 29 29 notes ...
Page 62: ...30 I1205 30 notes ...
Page 63: ...I1205 31 31 ...