I1205 | 17
17
|
installation
BRICK FLUE BAFFLE &
SECONDARY AIR TUBE
INSTALLATION
The flue baffle system located in the upper area
of the firebox is removable to make cleaning
your chimney system easier. The brick baffles
must be installed prior to your first fire.
Smoke
spillage and draft problems may occur if the
baffles are improperly positioned.
Check the
position of the brick baffles on a regular basis as
they can be dislodged if too much fuel is forced
into the firebox.
FIREBRICK ASSEMBLY
Firebrick is included to extend the life of your
insert and radiate heat more evenly. Check to
see that all firebricks are in their correct posi
-
DOOR HANDLE
Attach spring handle by rotating counter clock-
wise onto rod. Ensure that the rod fits into the
entire length of the spring handle.
Left = Open Right = Closed
Side View
Front View
Draft Rod
Front View
tions and have not become misaligned during
shipping.
DRAFT CONTROL
Before establishing your first fire, it is important
that your fully understand the operation of you
draft control. The draft rod is on the left side
of the Insert and it controls the intensity of the
fire by increasing or decreasing the amount of
air allowed into the firebox. To increase your
1)
If the two air tubes are installed continue
on to Step 2), if not, follow the instructions
below. Install the air tube into the holes in the
side channels. The notch goes on the right
hand side with the air holes facing toward
the door. Slide the tube into the left hand
side, as far as possible and then bring it back
into the hole on the right hand side until it
locks into position. If the tube will not slide
in easily simply use a pair of vise grips or
pliers and tap it into place with a hammer. A
tighter fit will ensure the tube will not move
when the unit is burning.
2)
Slide the left baffle brick over the front air
tube and then slide it back over the rear air
tube.
3)
Tilt the left baffle brick up on top of the side
channel and it will leave enough room to
position the right baffle brick in the same
manner as Step 1) above. Then reposition
the left baffle brick flat on the air tube.
4) Important: push both baffle bricks so
they are tight against the side walls and
to the back.
Note: When getting the chimney cleaned,
remove the baffle bricks for access
to the flue, then replace them when
cleaning is completed.
draft - slide left, and to decrease - slide right.
As well as a primary and glass wash air system,
the unit has a full secondary draft system that
allows air to the induction ports at the top of the
firebox, just below the flue baffle.
WARNING: To build a fire in ignorance or
to disregard the informa tion contained in
Summary of Contents for Classic I1205M
Page 25: ...Encastrable au bois Regency I1200 25 notes ...
Page 30: ...30 Encastrable au bois Regency I1200 garantie ...
Page 31: ...Encastrable au bois Regency I1200 31 ...
Page 60: ...28 I1205 28 warranty ...
Page 61: ...I1205 29 29 notes ...
Page 62: ...30 I1205 30 notes ...
Page 63: ...I1205 31 31 ...