background image

Regency CS2400  Freestanding Wood Stove

3

SAFETY LABEL

This is a copy of the label for reference only, that accompanies 
each 

CS2400  Wood Stove

. We have included a copy of the 

contents here for your review.

NOTE: 

 Regency units are constantly being improved.  Check 

the label on the unit and if there is a difference, the label on 
the unit is the correct one.

 

HOT WHILE IN OPERATION DO NOT TOUCH.  KEEP CHIL-

DREN, CLOTHING AND FURNITURE AWAY.

CONTACT MAY CAUSE SKIN BURNS. READ NAMEPLATE 

AND INSTRUCTIONS. 

CHAUD LORS DE FONCTIONNEMENT.

NE TOUCHER PAS. GARDEZ LES ENFANTS, VÊTEMENTS 

ET MEUBLES AU LOIN. 

LE CONTACT AVEC LE PEAU PEUT OCCASIONER 

DES BRÛLURES CUTANÉES.LIRE CETTE ÉTIQUETTE.

DO NOT REMOVE THIS LABEL

LISTED SPACE HEATER, SOLID FUEL TYPE,  ALSO 
SUITABLE FOR MOBILE HOME INSTALLATION 

MODEL:  

REGENCY  FREESTANDING STOVE -  CS2400

TESTED TO:  ULC S627-00 / UL 1482-2010 

REPORT NO:219-S-02d-2 

 

FLOOR 

PROTECTION*

K  405mm /16 in
L  150mm / 6in
M  150mm / 6in

CERTIFIED TO COMPLY WITH  JULY 1990, 

PARTICULATE EMISSION STANDARDS.

UNITED STATES  ENVIRONMENTAL 

PROTECTION  AGENCY

MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT         MAXIMUM ALCOVE DEPTH 915 MM / 36 IN.    
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18"
HAUTEUR MINIMALE DU PLAFOND DE L’ALCÔVE : 2,15 M / 7PI.   PROFONDEUR MAXIMALE DE L’ALCÔVE : 915 MM / 36 PO.

FOR USE WITH SOLID WOOD FUEL ONLY.  USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION.  DO NOT OBSTRUCT COMBUSTION 
AIR OPENINGS.  OPERATE ONLY WITH FIREBRICKS IN PLACE.  RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY CLOSED. IF INSTALLED IN 
A MOBILE HOME OPERATE ONLY WITH DOORS FULLY CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. WHEN OPERATED WITH DOORS OPEN THE MANUFACTURER 
SUPPLIED SCREEN MUST BE USED. DO NOT USE GRATE OR ELEVATE FIRE.  BUILD WOOD FIRE DIRECTLY ON HEARTH.  DO NOT OVERFIRE - IF HEATER OR CHIMNEY 
CONNECTOR GLOWS YOU ARE OVERFIRING.  INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY.  UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP 
MAY OCCUR RAPIDLY.  KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER.  REPLACE GLASS ONLY WITH NEOCERAM GLASS. COMBUSTIBLE 
FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND SIDES AS INDICATED OR TO THE NEAREST 
PERMITTED COMBUSTIBLE MATERIAL.
OPTIONAL COMPONENT: FAN (846-515), ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS, ASH DRAWER (220-516), ASHLIP (076-022), SIDE SHIELD (140-013/014)
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE.
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA:  LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH  LISTED CHIMNEY SYSTEM: SECURITY MODEL 
S2100, ICC EXCEL 2100, SELKIRK SENTINAL CF.
IN USA:   LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA VENT MODEL DVL, GSW 
SUPER PIPE 6, METAL-FAB DOUBLE WALL.  CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS SECURITY MODEL S2100 OR MODEL ASHT, SELKIRK 
MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR METAL-FAB TEMP/GUARD, AMERI-TEC HS,  ICC EXCEL 2100 .  USE CHIMNEY 
COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.

DÉGAGEMENT MINIMAL DU PLAFOND POUR UN CONNECTEUR HORIZONTAL : 455 MM / 18 PO.
L’ESPACE AU-DESSOUS DU POÊLE NE DOIT PAS ÊTRE OBSTRUÉ. UTILISER SEULEMENT AVEC LES BRIQUES RÉFRACTAIRES EN PLACE.
POUR UTILISATION AVEC BOIS SOLIDE SEULEMENT. L’UTILISATION D’AUTRES COMBUSTIBLES PEUT ENDOMMAGER LE POÊLE ET CRÉER UNE CONDITION DANGEREUSE. 
NE PAS OBSTRUER LES OUVERTURES D’AIR DE COMBUSTION. UTILISER SEULEMENT AVEC LA PORTE FERMÉE – OUVRIR LA PORTE DE CHARGEMENT POUR ALIMENTER 
LE FEU SEULEMENT. NE PAS UTILISER DE GRILLE À BÛCHES NI SURÉLEVER LE FEU. MONTER LE FEU DE BOIS DIRECTEMENT SUR L’ÂTRE. NE PAS SURCHAUFFER – SI 
LE POÊLE OU LE CONNECTEUR DE CHEMINÉE SE MET À ROUGIR, VOUS SURCHAUFFEZ. INSPECTEZ ET NETTOYEZ FRÉQUEMMENT LA CHEMINÉE ET LE CONNECTEUR. 
EN CERTAINES CONDITIONS D’UTILISATION, UN DÉPÔT DE CRÉOSOTE PEUT SE FORMER RAPIDEMENT. GARDEZ LES MEUBLES ET AUTRES MATÉRIAUX COMBUSTIBLES 
ÉLOIGNÉS DU POÊLE. REMPLACEZ LA VITRE SEULEMENT PAR DU VERRE EN NEOCERAM. LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR DES MATÉRIAUX NON 
COMBUSTIBLES DÉPASSANT DU DESSOUS, DU DEVANT ET DES CÔTÉS DU POÊLE, TEL QU’INDIQUÉ, OU JUSQU’AU MATÉRIAU COMBUSTIBLE LE PLUS PRÈS PERMIS.
COMPOSANTS EN OPTION : VENTILATEUR (846-515), ALIMENTATION ÉLECTRIQUE : 115 VOLTS, 60 HZ, 2 AMP., ASH DRAWER, SIDE SHIELD, ASHLIP
COMPOSANTS EXIGÉS POUR INSTALLATION DANS UNE MAISON MOBILE : KIT DE PRISE D’AIR EXTÉRIEUR ET L’UN DES CONNECTEURS DE CHEMINÉE À DOUBLE PAROI 
SUIVANTS :
AU CANADA : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, OU OLIVER MACLEOD PRO-VENT PV, AVEC SYSTÈME DE CHEMINÉE 
HOMOLOGUÉ : SECURITY MODÈLE S2100, ICC EXCEL 2100.
AUX ÉTATS-UNIS : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON 
DURA VENT MODÈLE DVL, GSW SUPER PIPE 6, METAL-FAB À DOUBLE PAROI. CONNECTÉ À L’UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS : SECURITY 
MODÈLE S2100 OU MODÈLE ASHT, SELKIRK MODÈLE SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODÈLE SC OU METAL-FAB TEMP/GUARD, AMERI-
TECHS, ICC EXCEL 2100. UTILISER LES COMPOSANTS DE CHEMINÉE SPÉCIFIÉS DANS LES INSTRUCTIONS D’INSTALLATION.

MADE IN CANADA

 JAN 

  FEB 

 MAR 

 APR 

 MA

Y

 

 JUN 

 JUL

 

 AUG  

 SEPT 

 OCT 

 NOV 

 DEC

CAUTION / ATTENTION:

DA

TE OF MANUF

ACTURE

2010

2012

201

1

918-927

MANUFACTURED BY: 

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.

 

6988 VENTURE ST.

 

DELTA, BC  V4G 1H4

duplicate serial number

370

370

  

 

* In Canada, fl oor pro-
tection must extend 18" 
(457mm) to the front 
and 8" (203mm) to each 
side of the stove.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

MEASURE 

FROM

SIDE SHIELDS/

BACK SHIELDS

FLUE

CENTRE-LINE

RESIDENTIAL INSTALLATION USING

 SINGLE WALL  CONNECTOR

SIDEWALL
BACKWALL
CORNER

A 18"      457mm
B 12"      305mm
C 6-1/2" 165mm

D 31"           787mm
E 20-3/8 "    518mm
F  19-3/16"  487mm

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  MOBILE HOME

SIDEWALL
BACKWALL
CORNER

A  15"     381mm
B  6.5"   165 mm
C  6"      152mm

D  28"               711mm
E  14-7/8""       378mm
F  18-11/16"     475mm

INSTALLER ET UTILISER SEULEMENT SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION DU FABRICANT.
CONTACTER LES RESPONSABLES DU BÂTIMENT OU DU SERVICE-INCENDIE DE VOTRE RÉGION POUR CONNAÎTRE LES RESTRICTIONS ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION. 
UTILISER UN CONNECTEUR D’UN DIAMÈTRE MINIMAL DE 150 MM (6 PO) 24 MSG EN ACIER NOIR OU 26 MSG EN ACIER BRONZÉ AVEC CHEMINÉE PRÉFABRIQUÉE HOMOLOGUÉE 
CONÇUE POUR UTILISATION AVEC COMBUSTIBLES SOLIDES OU UNE CHEMINÉE DE MAÇONNERIE.
VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT CONCERNANT LES PRÉCAUTIONS  EXIGÉES POUR INSTALLER UNE CHEMINÉE TRAVERSANT UN MUR OU 
PLAFOND EN MATÉRIAUX COMBUSTIBLES. NE FAITES PAS TRAVERSER LE CONNECTEUR DE CHEMINÉE DANS UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES. NE RACCORDEZ PAS 
CE POÊLE À BOIS À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.
CERTIFICATION DU MAISON MOBILE,  APPAREIL DE CHAUFFAGE AMBIANT HOMOLOGUÉ À COMBUSTIBLE SOLIDE, CONVENANT AUSSI POUR INSTALLATION DANS UNE MAISON MOBILE 

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  RESIDENTIAL CLOSE CLEARANCE

SIDEWALL
BACKWALL
CORNER

A  15"     381mm
B  6.5"   165 mm
C  6"      152mm

D  28"               711mm
E  14-7/8""       378mm
F  18-11/16"     475mm

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  ALCOVE

SIDEWALL
BACKWALL

G  15"       381mm
H  6-1/2"  165mm

I  28"           711mm
J  14-7/8"    378mm

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.  CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT 
RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.  USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103 
HT FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY.  
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.  DO 
NOT PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING.  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
MOBILE HOME CERTIFICATION, "ROOM HEATER SOLID FUEL TYPE, ALSO FOR USE IN MOBILE HOMES."

Summary of Contents for CS2400

Page 1: ...Canada V4G 1H4 918 926a CS2400 Alterra Freestanding Wood Stove 02 15 12 Owner s Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference ...

Page 2: ...Y DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTES If this wood stove is not properly installed a house fire may result For your safety follow the installation instructions contact local building or fire officials about restrictions and installation inspection requirements in your area This appliance needs fresh air for safe operation and must be installed with adequate combustion...

Page 3: ...TEUR EN CERTAINES CONDITIONS D UTILISATION UN DÉPÔT DE CRÉOSOTE PEUT SE FORMER RAPIDEMENT GARDEZ LES MEUBLES ET AUTRES MATÉRIAUX COMBUSTIBLES ÉLOIGNÉS DU POÊLE REMPLACEZ LA VITRE SEULEMENT PAR DU VERRE EN NEOCERAM LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR DES MATÉRIAUX NON COMBUSTIBLES DÉPASSANT DU DESSOUS DU DEVANT ET DES CÔTÉS DU POÊLE TEL QU INDIQUÉ OU JUSQU AU MATÉRIAU COMBUSTIBLE LE PLUS ...

Page 4: ... 14 Listed Components For Mobile Home Installation 14 Stainless steel smoke deflector Installation 15 Flue Baffle Secondary Air Tube Installation 16 Brick Installation 16 Door Handle 16 Side panel Installation 17 Ash drawer option 18 Lower Surround door reversal 19 Cast Door reversal 20 Wood Storage 21 Ashlip Installation 21 Optional outdoor Air kit installation 22 Blower Fan installation 23 Fan O...

Page 5: ...tove 5 DIMENSIONS UNIT DIMENSIONS 17 3 16 39 1 8 41 1 8 25 15 16 44 7 8 23 3 8 28 7 8 21 1 2 26 3 8 26 5 16 26 5 16 8 5 16 17 1 8 CL for outside air 27 5 16 to rear shield to optional fan Shown with optional fan installed 6 flue collar ...

Page 6: ...be connected to any air distribution duct INSTALLATION CHECKLIST 1 Locate appliance a Refer to Residential Installation section b Clearances to Combustibles Refer to Clearances section c Alcove Clearance Refer to Alcove Clearance section d ChimneyRequirements Referto Masonry Chimney Factory Built Chimney Combustible Wall Chimney Connector Pass Throughs section 2 Minimum Flue Height Refer to Minimu...

Page 7: ...line CS2400 A B C D E F 18 12 6 5 31 20 3 8 19 3 16 Residential Close Clearance To be installed with required pipe components When the stove is installed as a close clearance residential unit a listed double wall connector is required from the stove collar to the ceiling level From Unit From Corner From Flue Center line CS2400 A B C D E F 15 6 5 6 28 14 7 8 18 11 16 Mobile Home Close Clearance To ...

Page 8: ...r the rear clearance to combustibles whichever is smaller from the rear of the stove NOTE In Canada floor protection must extend 18 to the front and 8 to each side of the stove Minimum Alcove Clearance to Combustible Materials Unit From Back Shield Side Shields From Flue Center Line Min Width Min Hearth to Rear Wall CS2400 G H I J K L 15 6 5 28 14 7 8 56 47 1 2 Minimum Overall Depth Y of Floor Pro...

Page 9: ...t is recommended that no ceiling support member be cut for chimney and support box installation If it is necessary to cut them the members must be made structurally sound 2 Install radiant shield and support from above 3 Stacktheinsulatedpipeontoyourfinishsupport to a minimum height of 3 feet above the roof penetration or 2 feet above any point within 10 feet measured horizontally There must be at...

Page 10: ... inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned beforethestoveisinstalledandoperated Whenconnect ing the stove through a combustible wall to a masonry chimney special methods are needed Ensure that an effective vapour barrier at the location where the chimney or other component penetrates to the exterior ...

Page 11: ...clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a minimum 24 gage 024 61 mm 6 152 4 mm metal chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minim...

Page 12: ...00 16 0 17 0 18 5 20 0 24 0 21 0 26 5 9000 10000 16 5 17 5 19 0 20 5 24 5 22 0 27 0 NOTE No more than two offsets four elbows allowed Two 45o elbows equal one 90o elbow RECOMMENDED HEIGHTS FOR WOODSTOVE FLUE Simple rules on draft See Table 1 1 At sea level minimum height is 12 straight 2 Addthefollowingverticalheighttocompensate for 45 deg elbow 1 ft 90 deg elbow 2 ft T 3 ft Each foot of horizonta...

Page 13: ... Use 4 duct pipe with a mesh grill to pipe fresh air into the back shield area Place your unit in position and secure it to the floor using two lag bolts 3 8 x 3 1 2 through the two holes inside the pedestal base See page 9 for installation instructions For Mobile Home units installed in the U S the unit must be grounded using a 8 ground wire with approved termination and star washer Secured to fl...

Page 14: ...ion 1 DL42A 6 Connector Kit 1 6XSF Support 1 6XFA Flashing 1 6XL3 Chimney Length 1 6XL18 Chimney Length 1 6XCPE Rain Cap METAL FAB TEMP GUARD 2100 Qty Part Description 1 6DWBK Connector 1 6TGRS Roof Support 1 6TGG36 Chimney Length 1 6TGG12 Chimney Length 1 6TGF Flashing 1 6TGC Rain Cap AMERI TEC HS Qty Part Description 1 6DCC Connector 1 6HSRS 12 Roof Support 6PLRS 12 BK 1 6F Flashing 1 6HS 36 Chi...

Page 15: ...out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector installed with 2 bolts Note This is a view from the back of the unit through the top Smoke deflector is installed through the door opening in location shown in diagram Ensur...

Page 16: ...ue on to Step 2 if not follow the instructions below Install the air tube into the holes in the side channels The notch goes on the right hand side with the air holes facing toward the door Slide the tube into the left hand side as far as possible and then bring it back into the hole on the right hand side until it locks into position If the tube will not slide in easily simply use a pair of vise ...

Page 17: ...t to the unit Failure to do this will result in burn stains on panels which you will be unable to remove Not protected by product warranty One set of side panels needs to be installed on the stove When installing stainless steel side panels follow the handling and cleaning instructions below 1 Bend the metal tab located in the top front corner of the side panels to a 45 angle with a pair of pliers...

Page 18: ...al in operating instructions 1 Open the main top door and the center door on the front of the unit 3 Remove the ash dump cover plates one inside the firebox and one on the underside of the firebox access the lower plate through the center door it is directly below the upper ash dump plate by removing the two nuts and bolts holding the 2 plates together from underneath the stove Ash Dump Plates Ash...

Page 19: ...tained within the manual package Rotate the hinge 180 and reinstall on the right side 4 Rotate both hinge and latch 180 and reinstall hinge on left side latch on right side 5 Remove and rotate both the male part of the latch 180 located on the inside of the lower surround door Install the latch on the opposite side of the door Door latch male portion 6 Reinstall the door do not rotate onto the hin...

Page 20: ...curing the door catch assembly to the unit 6 Remove the glass from the door and flip it around 180 so the painted strip is at the bottom of the door 7 Flip the handle around 180 and reattach to the door with 2 botls 4 Flip the door hinge 180 install on the left side of the unit with 2 bolts 5 Reattach the door catch assembly on the right side with 2 bolts from step 3 Door Catch Door Catch Door Hin...

Page 21: ... within pedestal Note Please refer to local codes B365 NFPA211 and your local jurisdiction Store wood behind opening 1 Open lower surround door 2 Ashlip to be positioned just below the ashdrawer if installed 3 Manoeuvre ashlip into position on an angle the tabs on the ashlip rest behind side walls on unit see diagrams below Tabs on ashlip Final install of Ashlip Ashlip to be positioned here ...

Page 22: ...crews from locations shown below to remove backing plate 2 Center the plate pipe over the opening on the back of the stove Secure with 4 self tapping screws 3 Reinstall the backing plate over the air kit pipe Secure with 4 screws removed from step 1 4 Slide cap over end to pipe to complete the installation ...

Page 23: ...with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly groundedthree prongreceptacle Donotcutorremove the grounding prong from this plug NOTE This appliance when installed must be electrically grounded in accord ance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian E...

Page 24: ...flamemaybedrawnout of the fireplace stove opening creat ing risks from both fire and smoke DRAFT CONTROL Both the primary and air wash drafts are controlled by the control rod located on the left side of the unit when facing the unit To increase your draft pull open and to decrease push closed All units have a secondary draft system that continually allows combustion air to the induction ports at ...

Page 25: ...hes out of the stove when the stove is cold Remove the plug by lifting on the handle using the tool provided Push the ashes down the hole into the ash drawer the large pieces can be left in the firebox and burned during the next fire or removed through the door opening 2 Always leave 1 2 to 1 inch of ash in the bottom of the firebox This helps in easier starting and a more uniform burn of your fir...

Page 26: ...thods for supporting fuel Burn directly on the bricks 11 Open the draft control fully for 10 to 15 seconds prior to slowly opening the door when refuelling the fire 12 Do not connect your unit to any air distribution duct 13 Your woodstove must burn dry seasoned standard firewood only The use of cut lumber plywood mill ends coal charcoal etc is prohibited as this fuel can easily over heat your woo...

Page 27: ... stove and remove the glass retainer Use caution when removing broken glass to avoid injury When placing the replacement glass in the door make sure that the glassgasketingwillproperlysealyourunit Replace the retainer it should rest on the gasket not the glass and tighten securely with a glass clips and screws Do not wrench down on the glass as this may cause breakage Do not use substitute materia...

Page 28: ...t Test the seal on the loading door with a paper bill Place a paper bill in the gasketed area of the door on a cold stove close the door Try to remove the paper by pulling The paper should not pull out easily if it does try adjusting the door latch if that doesn t solve the problem replace the door gasket Check and lubricate door hinge latch Use only high temperature anti seize lube ie never seize...

Page 29: ...nt Leg 6 076 011 Rear Fan Clip 7 200 917 Fan Assembly 8 146 003 Side Shield LH 9 146 002 Side Shield RH 10 146 514 Pedestal Assembly 11 156 523 Door Hinge Assembly 12 220 516 Ash Drawer Assembly 13 156 523 Door Catch Assembly 14 146 517 Heat Shield Assembly 15 146 517 Back Shield Assembly 16 146 512 Firebox Assembly 17 146 011 Top Bottom Vents 18 146 008 Side Support 19 948 216 Regency Logo plate ...

Page 30: ...ght Hand 5 200 228 Fan Bracket Left Hand 6 200 229 Fan Housing Back 7 910 157 P Fan 8 910 142 Thermodisc Part Description 1 020 960 Firebrick Set 2 033 953 Air Tube 3 4 Qty 4 3 020 957 Baffle set RED LOW WHITE COMMON CONNECTION DIAGRAM BLACK HIGH 115V 60HZ 1 1A J250 150 O44003 T P 3000 RPM JAKEL INC DATE T P L B 5 6 2 3 4 7 8 1 FAN ASSEMBLY FIRE BRICK AIR TUBE BAFFLE 3 1 2 ...

Page 31: ... or costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type of unit problem and part or pa...

Page 32: ..._________________________________________ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and special offers ...