39
39
|
installation
Diagram 1.8
Diagram 1.9
Diagram 1.10
Diagram 1.11
Diagram 1.13
Diagram 1.12
11
. Remove Top Front Flange of Firesong firebox. (See Diagram 1.8).
Remove tabs on right and left side of firebox.
12.
Cut out mid section of Firesong firebox . (See Diagram 1.9).
Cut off bar at back of firebox.
14.
Cut out right side of existing Firesong firebox. (See
Diagrams1.11,1.12 and 1.13). Left and right cutout begins on
front face - see diagram 1.12
IMPORTANT
: Cut out Firesong firebox and install support one side
at a time.
Back bar
13.
Remove 6 screws, one at a time, and replace with pan head
(wafer screws) - in locations shown below.