58
|
Regency
®
E18 Gas Fireplace Insert
|
58
installation
Access Panel
On / Off Switch
Fan Speed Control
Flame Control
Fireplace Controls
The E18 has 3 controls for
controlling flame height, fan speed
and flame on/off. The fan on the
E18 is designed to come on once
the fireplace has reached a pre-
determined temperature, and to go
off once the temperature has
dropper following use.
The speed of the fan can be varied
by adjusting the Fan Speed Control
dial up or down. These controls are
located to the left side of the
Surround Panels.
Providing that the pilot system is in
standing mode, the main burner
can be turned on or off by way of a
switch located just below the Fan
Speed Control dial. See the Lighting
Instruction section in this manual
for information on lighting the pilot.
The flame height can be adjusted
from minimum to maximum by way
of an adjustment knob on the
Control Valve, located behind the
Access Panel. The Access Panel is
held in place by magnets and can
simply be lifted away from the unit
and set aside.
SAFETY SWITCHES
The E18 uses two safety switches to maintain proper operation.
The first is a Spill Switch which will shut off the appliance if continuous spilling of exhaust gas from the drafthood occurs. The spill switch will shut off the
Main Burner but not the Pilot. This switch is resets automatically, if the problem persists the appliance will cycle on and off. If this occurs. shut the unit off and
contact a technician.
The second is a Primary Limit Switch. This switch confirms that the circulation fan is operating normally. If for any reason the circualtion fan fails, the Primary
Limit Switch will turn off the Main Burner but not the Pilot before the appliance becomes too hot. This switch is automatic resetting, so if the problem persists
you will see your appliance cycling on and off. If this occurs shut the unit off and contact a technician.
OPERATION CONTROLS
FIREPLACE CONTROLS
The E18 has 3 controls for controlling flame height, fan
speed and flame on/off. The fan on the E18 is designed
to come on once the fireplace has reached a pre-deter-
mined temperature, and to go off once the temperature
has dropper following use.
The speed of the fan can be varied by adjusting the Fan
Speed Control dial up or down. These controls are located
to the left side of the Surround Panels.
Providing that the pilot system is in standing mode, the
main burner can be turned on or off by way of a
switch located just below the Fan Speed Control dial.
See the Lighting Instruction section in this manual
for information on lighting the pilot.
The flame height can be adjusted from minimum to maxi-
mum by way of an adjustment knob on the Control Valve,
located behind the Access Panel.
The Access Panel is held in place by magnets and can
simply be lifted away from the unit and set aside.
Note:
Supplied white cord channel
Use cord channel to obscure cord and keep tidy. The
cord is located on the left hand side of the appliance.
1.
Open channel and feed cord through.
2.
Peel off backing of cord channel and adhere to hearth.
Diagram 15.1