background image

* Only available in British Columbia to accredited dealers.

E18* Gas Insert

Model

E18-NG

E18-LP

Fuel Type

Natural Gas

Propane Gas

Minimum Supply Pressure

5” W.C.

(1.25 kPa)

12” W.C.

(2.99 kPa)

Manifold Pressure - High

3.5” W.C.

(0.87 kPa)

10” W.C.

(2.49 kPa)

Manifold Pressure - Low

1.6” W.C.

(0.40 kPa)

6.4” W.C.

(1.60 kPa)

Orifice Size

#44 DMS

#55 DMS

Minimum Input  

Altitude 0-4500 ft.

(0-1372m)

15,000 BTU/h (4.40 kW)

17,000 BTU/h (4.98kW)

Maximum Input 

Altitude 0-4500 ft.

(0-1372m)

21,600 BTU/h (6.33kW)

20,500 BTU/h (6.01 kW)

  13 3/4"

349mm

 

 23 15/16"

608mm

 

  14 9/16"

370mm

 

  34 7/16"

875mm

 

3 15/16"

100mm

 

11"

280mm

 

  16 5/8"

423mm

 

  23 9/16"

598mm

 

  29 7/16"

747mm

 

  7 1/4"

184mm

 

 1 15/16"

50mm

 

  Verify the model of the E18 will replace 

is one of the following approved units:

 

Montigo EP28-2
Montigo EP28-4
Montigo EP28-5
Montigo Econo Plus 28C
Montigo EP28-S2
Montigo 36SR (Non powervent unit)
Montigo 28F-2
Montigo 28-F
Firesong 220N
Firesong 120N