background image

6

Regency

®

 F33-3 Freestanding Gas Stove

Regency Freestanding Gas

PEDESTAL ASSEMBLY

1)

  For easier assembly, tip the stove on its back (preferably onto a 

soft surface to prevent scratching).

  

2)

  Unscrew the 4 bolts in the underside of the stove. Align the holes 

in the corners of the pedestal top with the corresponding holes in 

the base of the stove.  Use washers which are supplied with the 

pedestal as shown in diagram. Reinstall bolts.

3)

  Push the Regency

®

 logo into the two holes in the front bottom left 

corner of the pedestal cover plate.

 

Note: Any paint touch up should be done prior to placing logo 

on pedestal.

4)

  See wiring instructions below.

Diagram 1

INSTALLATION

2)

  If required, adjusting the primary air to ensure that the flame does 

not carbon. First allow the unit to burn for 15-20 min. to stabilize.

3)

  Check for proper draft.

CAUTION:

 Any alteration to the product that causes sooting or carboning 

that results in damage is not the responsibility of the manufacturer.

CLEARANCES TO COMBUSTIBLES

The clearances listed below are MINIMUM distances.  Measure the 
clearance  to  both  the  appliance  and  the  chimney  connector.   The 
farthest distance is correct if the two clearances do not coincide. For 
example, if the appliance is set as indicated in one of the diagrams but 
the back wall is too close, move the stove until the correct clearance 
to the connector is obtained.  

This appliance may be installed only with the clearances as shown 
in the situations pictured.  Do not combine clearances from one type 
of installation with another in order to achieve closer clearances. Use 
the minimum clearances shown in the diagrams.

F33-3 Clearance to Combustibles

A  Side Wall to Unit 

 

250  mm

B  Back Wall to Unit 

 

150  mm

E  Side Wall to Unit 

 

 38  mm

F33-3 Reference Dimensions

C  Back Wall to Flue Centerline 

292  mm

D  Side Wall to Flue Centerline 

559  mm

F  Side Wall to Flue Centerline 

330  mm

Minimum ceiling height is 914 mm from top of 
unit.

Summary of Contents for F33

Page 1: ...lt an authorized installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flam mable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorized installer service agency or the gas supplier PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Owners Installation Manual LISTINGS AND CODE APPR...

Page 2: ...u with all the warmth and charm of a woodstove at the flick of a switch The models F33 NG3 and F33 LPG3 have been approved by the Australian Gas Association for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many ...

Page 3: ...lation 12 Optional Wall Thermostat Installation 12 Thermostat Wire Table 12 Final Check 12 OPERATING INSTRUCTIONS Operating Instructions 13 Lighting Procedure 13 Shutdown Procedure 13 Copy of the Lighting Plate Instructions 14 MAINTENANCE Normal Operating Sounds of Gas Appliances 15 Maintenance Instructions 15 General Flue Maintenance 16 Log Replacement 16 Gold plated Doors 16 Glass Replacement 16...

Page 4: ...on Grey Size 100 Sept 22 09 updated standard removed 2000 from As4553 Feb 3 10 Changed distributor address Sept 12 12 Updated Code Dec 24 13 Rev F updated E Aus address and formatting of code July 5 16 Updated with NZ address added Nov 8 16 Rev G Updated F33 unit name Electrical 240VAC 50Hz 1 0 amp max Serial Number 918 092g Model N2134 Regency Gas Fireplace 3 0mm 1 15mm 2 7mm 1 6mm AS4553 227 AGA...

Page 5: ... the appliance to ensure the correct firing rate rate noted on label after burning appliance for 15 minutes BEFORE YOU START INSTALLATION AND REPAIR SHOULD BE DONE BY AN AU THORISED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY AN AUTHORISED SERVICE PERSON MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROMCARPETING BEDDINGMATERIAL ETC ITISIMPER...

Page 6: ...sessootingorcarboning that results in damage is not the responsibility of the manufacturer CLEARANCES TO COMBUSTIBLES The clearances listed below are MINIMUM distances Measure the clearance to both the appliance and the chimney connector The farthest distance is correct if the two clearances do not coincide For example if the appliance is set as indicated in one of the diagrams but the back wall i...

Page 7: ...tom Shield or Pedestal 10 ConnecttheorangewirefromthespillswitchtotheBurnerON OFF switch 11 Re connect the fan harness plug 12 Secure the power cord with the supplied grommet at the back of the Bottom Shield or Pedestal LEG AND BOTTOM SHIELD ASSEMBLY These instructions apply to the black gold and nickel cast legs It will be easier to attach the legs to the stove if it is tipped on its back prefera...

Page 8: ...open position Before trying to start up the unit make sure the red button on the spill switch is pushed in FLUEING REQUIREMENTS 100mm diameter flue is required in accordance with AS5601 2004 NZS 5261 or any relevant local building codes For altitudes above 610m we recommend that a minimum flue height of 3 6m is used WIRING CAUTION Label all wires prior to disconnection when servicing controls Wiri...

Page 9: ... correct operating pressure For minimum and maximum supply pressure see the System Data table below Note During any pressure testing of the gas supply piping system that exceeds test pressures of 3 45 kPa this ap pliance and its individual shut off valve must be discon nected from the piping system If test pressures equal to or less than 3 45 kPa are used then this appliance can be isolated from t...

Page 10: ...in the larger logs See diagrams 1 2 Carefully push the cross logs onto the pins Diagram 1 TEST FOR FLUE SPILLAGE This heater must be properly connected to a flue system WARNING Operation of this heater when not connected to a properly installed and maintained flue system or tampering with the flue safety shutoff system can result in carbon monoxide CO poisoning and possible death A spillage test m...

Page 11: ...embers along the mesh ember tray but do not cover the burner ports Burner ports are the little holes on the top of the burner tube Pull off ember size pieces from the rock wool Gently place the pieces on top of the embers See diagram 3 Do not put the rock wool directly on the burner Close the door and turn the unit on as per lighting instructions Watch the flame to see if it flows smoothly around ...

Page 12: ...battery in both receiver and the transmitter Install the receiver and cover in the wall The remote control is now ready for operation OPTIONAL WALL THERMOSTAT INSTALLATION A wall thermostat may be installed if desired Note Preferable if the thermostat is installed on an interior wall Use a CSA UCL or UL approved millivolt thermostat 250 750 millivolt rated A non anticipator type thermostat must be...

Page 13: ...The FIRST FIRE in your stove is part of the paint curing process To ensure that the paint is properly cured it is recommended that you burn your fireplace for at least four 4 hours the first time you use it with the fan on When first operated the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufacturing Smoke detectors in the house ma...

Page 14: ...ctly a fire or explosion may result causing propertydamage personalinjuryorlossoflife Improperinstallation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier ...

Page 15: ...ons Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean brush as the logs are fragile and easily damaged 2 Clean appliance and door with a damp cloth never when unit is hot Never use an abrasive cleaner The glass should be cleaned with a gas fireplace glass cleaner when it starts to cloud up 3 The heater is finished i...

Page 16: ...nt that you break your glass by impact purchase your replacement glass from an authorized Regency dealer only and follow our step by step instructions for replacement 1 Allow the stove to cool before removing or replacing glass 2 To remove the door from the stove remove the securing screw lo cated between the ashlip and the door then unfasten the latch 3 Remove gold hinge caps from door 4 Lift doo...

Page 17: ...eckthepilotflames Correctflamepatternhasthree strong blue flames 1 flowing around the thermopile 1 around the thermocouple and 1 flowing across the burner it does not have to be touching the burner Note If you have an incorrect flame pattern contact your Regency dealer for further instructions MAINTENANCE Incorrect flame pattern will have small probably yellow flames not coming into proper contact...

Page 18: ...Piezo Igniter by removing two 2 sheet metal screws 10 Loosen four 4 phillips head M5 valve mounting screws from un derside of firebox Push valve assembly forward on the teardrop slots and drop down 11 Disconnect Piezo wire To remove valve from valve assembly continue 12 Remove two 2 thermopile wires 13 Remove thermocouple with a 9 mm metric spanner 14 Remove pilot nut with an 11 mm spanner 15 Remo...

Page 19: ...ate by removing 4 screws See diagram 1 Diagram 1 3 Remove valve cover plate by removing 2 screws 4 Disconnect the molex plug from inside the stove Note The 8 ground lug is a dedicated ground for mobile home use only 5 Loosen the four 8 32 x 1 2 screws provided into the nutserts as shown in diagram 3 NOTE Make sure the fan is supported as it may fall when the 4 screws are loosened Diagram 2 Ground ...

Page 20: ...n and or adjust pilot so pilot is enveloped around thermopile and thermocouple Be sure wire connections at gas valve terminals are tight and ther mopile and thermocouple are fully inserted into pilot bracket One of the switch wires may be grounded May be grounded to gas appliance or gas supply Check thermopile with millivolt meter Take reading at thermopile terminals of valve TP TPTH Should read 2...

Page 21: ...46 973 Door Handle Latch Assembly 10 910 714 Power Cord 240 V 11 910 006 Terminal Block 12 846 570 7 8 Door Gasket Repair Kit 13 846 918 Hinge Cap Gold Plated 2 set 14 Screw 10 24 x 3 4 Pan Head 15 Washer 1 4 split lock 16 Screw 10 24 x 1 2 Pan Head 17 471 031 Door Retainer Clip 19 948 101 Spring Handle Large 490 918 Packaged Fan Assembly 20 910 155 P Fan Blower Motor 240V 21 910 142 Thermodisc Fa...

Page 22: ...10 035 Pilot Assembly 3 flame SIT LPG 67 904 604 Orifice 36 NG 904 390 Orifice 52 LPG 68 948 294 Burner NG 69 948 279 Burner LPG 70 Complete Burner Tray Assy SIT NG 71 Complete Burner Tray Assy SIT LPG 72 490 023 Front Log Deflector NG LPG 75 490 068 Rear Log Deflector Top LPG 79 460 011 Rear Burner Deflector Back NG 490 932 Complete Log Set 80 Front Log 81 Rear Log 82 Top Log each 902 151 Ember 9...

Page 23: ... cord 121 Access Panel 140 850 127 Cast Legs Gold 850 126 Cast Legs Black 850 128 Cast Legs Brush Nickel 142 850 125 Steel Legs Pedestal Assembly 490 926 Complete Pedestal 100 948 216 Logo Plate Regency 102 904 257 Magnetic Catch Large 103 11 Pedestal Hinge 108 910 246 Burner ON OFF Switch 109 910 140 Fan Hi Off Low Switch 110 Strain Relief for power cord 123 Pedestal Blanking Plate 124 820 058F P...

Page 24: ...omponents Ignition Control Boards Wiring Switches Fans Fan Control Module Battery Pack Remote Control Systems 1 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Fire beads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 After the original warranty coverage for any of the parts abov...

Page 25: ...eneral practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect If a consumer has a unit installed outside an accredited distributor dealer or pre approved service agent s service area or the closest approved service agent is situated more than thirty 30 kilometres from the insta...

Page 26: ...movement expansion and contraction of the steel is normal and is not covered under the terms of this warranty Freight damages for products or parts are not covered under the terms of the warranty Porcelain Enamel Absolute perfection is neither guaranteed nor commercially possible Any chips must be reported and inspected by the authorised selling dealer within three 3 days of installation Any damag...

Page 27: ...o at the option of the supplier one or more of the following i replacement of the goods or the supply of equivalent goods ii the repair of the goods iii the payment of the cost of replacing the goods or of acquiring equivalent goods or iv equivalent goods or v the payment of the cost of having the goods repaired b To the extent that services supplied by the supplier are services other than service...

Page 28: ...rvices Fireplace Products Australia Pty Ltd 1 3 Conquest Way Hallam VIC Australia 3803 Phone 61 3 9799 7277 Fax 61 3 9799 7822 To obtain warranty service in Western Australia and or New Zealand please contact one of our authorised distributors in those areas Western Australia Air Group Australia 28 30 Division St Welshpool WA Australia 6106 Phone 08 9350 2200 Fax 08 9353 4225 New Zealand Aber Hold...

Page 29: ...in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases ma...

Page 30: ...30 Regency F33 3 Freestanding Gas Stove ...

Page 31: ...Regency F33 3 Freestanding Gas Stove 31 ...

Page 32: ...__________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Copyright 2019 FPI Fireplace Products International Ltd All rights reserved ...

Reviews: