F3500 Regency Freestanding Woodstove
19
installation
BRICK INSTALLATION
Firebrick is included to extend the life of your stove and radiate heat more evenly. Install all firebricks per the diagram below and place in their correct positions.
Do not use a grate.
1.
Remove box of firebricks from inside unit.
2.
Remove Lyotherm sheet from mailer tube and install on base of firebox as shown below.
NOTE:
The "AD" brick covers the Ash Dump hole that is used when the Ash Drawer Kit is installed.
Lyotherm sheet
Final Install
3.
Order of firebrick install:
a) Rear Firebrick
b) Firebox floor - install brick over Lyothern Sheet
c) Right and left side Firebricks
AD brick
Fire bricks
#
Size
1
4-1/2" x 9"
2
4" x 9"
3
3-1/2" x 4-1/2"
4
1-3/4" x 4-1/2"
5
4-1/2" x 7-5/8"
6
1-3/4"" x 9"
CHK
PROCESS :
SCALE:
DWN
BLANK SIZE :
SIGN
C.N.
DATE
THIS DRAWING IS THE PROPERTY OF FPI LTD., IT MAY NOT BE COPIED IN WHOLE OR IN PART, OR DISCLOSED TO A THIRD PARTY WITHOUT OUR PRIOR WRITTEN CONSENT.
CURRENT REVISION
PREVIOUS REVISION
PART :
MAT'L :
ANGULAR =
INSIDE BEND RADII =
UNITS IN INCHES
DIMENSIONS =
TOLERANCES UNLESS
OTHERWISE STATED
SCALE
DO NOT
PROJECTION
3RD ANGLE
MODEL #
QTY.
REV.
±1°
±0.031
PART
NO.
FIREPLACE PRODUCTS INTERNATIONAL
06 MAY 2013
N/A
ASSEMBLY
-
042-960
WAYNE THURBER
042-960
FIRE BRICK ASSEMBLY
-
F3500
1
1:8
10.281
22.855
17.935
6
3
4
5
1
2
Mass = 32.361 pounds
6
802-146
1
1.750 x 9.000 BRICK
5
802-165
1
7.375 x 4.500 CUT BRICK
4
802-128
1
1.875 x 4.500 BRICK
3
802-147
1
3.500 x 4.500 BRICK
2
802-104
1
4.000 x 9.000 BRICK
1
902-111
15
9.000 x 4.500 STANDARD BRICK
ITEM
NO.
PART NUMBER QTY.
DESCRIPTION