30
F3500 Regency Freestanding Woodstove
maintenance
SECONDARY AIR TUBE REMOVAL /
INSTALLATION
1.
Allow the stove to burn out and cool down, until cool to touch.
2.
Open stove door to access secondary air tube.
3.
Grasp secondary air tube firmly with vise grips, using a hammer tap vise
grips from right to left until air tube is released from grip. Remove.
Secondary Air
Tube
DOOR CATCH
ADJUSTMENT
After a few fires, the door catch may require adjustment to renew a tight seal,
as the door gasket will compress. Removal of a shim, shown in the diagram
below, will allow the catch to be moved closer to the door frame, creating a
tighter seal.
To remove a shim, loosen the 2 bolts to create clearance behind catch. Place
a screwdriver in the slot of the shim and slide out. Retighten bolts.
Note: Keep the shims - they may be required in the future when the gasket
is replaced.
3.
To reinstall or replace, first slide left side of tube into hole on left side air
channel. Align tab on right side air channel with notch on right hand end of
air tube. Firmly grip center of air tube with vise grips, use hammer to tap vise
grips from left to right until the tube bottoms out into the air channel on right.