8
F3500 Regency Freestanding Woodstove
installation
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS
Please read the section below carefully as clearances depend on whether the Airmate or the Rear Heat Deflector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall.
Clearances may only be reduced by means approved by the regulatory authority.
Note: Minimum ceiling height roof - 83"
(2108 mm)
B
A
D
E
F
F
C
C
NOTE:
Be aware that local Codes and
Regulations may override some
clearances listed in this manual.
Check with your local inspector.
Residential Close Clearance (To be installed with required pipe components) Listed Double Wall Pipe
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling level.
F3500
with Airmate or
Rear Deflector
A
B
C
D
E
F
11"
279mm
9-1/2"
241mm
8"
203mm
24"
610mm
16"
406mm
20-1/2"
521mm
Residential Installation "C" Vent (Single Wall Pipe)
F3500
with Airmate or
Rear Deflector
A
B
C
D
E
F
11"
279mm
9-1/2"
241mm
8"
203mm
24"
610mm
16"
406mm
20-1/2"
521mm
Mobile Home Close Clearance (To be installed with required pipe components) Listed Double Wall Pipe
When
the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling level.
Refer to Mobile Home Installation in this manual.
F3500
with Airmate or
Rear Deflector
A
B
C
D
E
F
11"
279mm
9-1/2"
241mm
8"
203mm
24"
610mm
16"
406mm
20-1/2"
521mm
Minimum Alcove Clearance to Combustible Materials
The Regency Freestanding models have been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 83"
(2108 mm) Vertical Termination}
H = Maximum depth of alcove - 48"
(1219mm)
G= Minimum width of alcove - 60"
(1524mm)
B
A
D
E
H
G
ROOF EXIT
WALL EXIT
ROOF EXIT
WALL EXIT
ROOF EXIT
WALL EXIT
NOTE:
Clearances to combustibles are for
the safety of the property. To avoid
overheating and damaging the
appliance these clearances should
be maintained for non-combustibles
also.
NOTE: This clearance is also required for air space between the appliance and wall/ceiling.
NOTE: This clearance is also required for air space between the appliance and wall/ceiling.