FG39-2 Freestanding Gas Stove
23
installation
Conversion Kit for NG to LPG Part #360-968
919-867
04.19.18
1
FG39-2
Conversion Kit contains:
Qty. Part #
Description
1 904-529
4m Allen Key
1 904-641
Burner Orifi
ce #50
1 918-590
"Converted to LPG" label
1 919-728
Orange "Propane" label
1 910-037
#30 LP Pilot Orifi
ce
1 919-867
Instruction Sheet
1.
Shut off
the gas supply and unplug the
power cord.
2. Open the front door and carefully remove
the logs and lava rock.
3. Remove burner.
4. Remove burner ori
fi
ce with a 13mm
wrench and discard. Use a wrench to hold
on to the elbow behind the ori
fi
ce.
5. Reinstall new burner ori
fi
ce LPG stamped
#50 and tighten.
Burner Orifi
ce
6. Pull out the pilot hood by hand.
Pilot
Hood
Pilot
Hood
removed
7. Remove the pilot ori
fi
ce with the Allen key.
Pilot
Orifi
ce
8. Put in the new LPG ori
fi
ce with the Allen
key. Then put back the pilot hood.
9. Place the pilot hood back on.
10. Adjust the burner aeration setting to
fully
open
and install the burner.
11. Remove the pedestal back cover by remov-
ing the 4 Phillips screws.
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
FG39-2 Conversion Kit #360-968 from NG to LPG