32
FG39-2 Freestanding Gas Stove
maintenance
LOG REPLACEMENT
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door to carefully remove the logs.
The pilot light generates enough heat to burn
someone. If for any reason a log should need
replacement, you must use the proper replace-
ment log. The position of these logs must be as
shown in the diagram under Log Installation.
Note: Improper positioning of logs may
create carbon build-up and will alter
the unit’s performance which is not
covered under warranty.
DOOR GASKET
If the door gasket requires replacement use
22mm diameter oval door gasket.
LATCH ADJUSTMENT
The door latch may require adjustment as the
door gasket material compresses after a few fires
and after glass replacement. Turn the adjustable
catch to tighten or loosen the latch.
CAUTION: ANY SAFETY SCREEN
OR GUARD REMOVED FOR SER-
VICING AN APPLIANCE MUST BE
REPLACED PRIOR TO OPERAT-
ING THE APPLIANCE.
CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT
BE PLACED ON OR NEAR THE
APPLIANCE.
DO NOT USE THIS APPLIANCE
IF ANY PART HAS BEEN UNDER
WATER. IMMEDIATELY CALL AN
AUTHORIZED SERVICE TECHNI
CIAN TO INSPECT THE APPLI-
ANCE AND TO REPLACE ANY
PART OF CONTROL SYSTEM AND
ANY GAS CONTROL WHICH HAS
BEEN UNDER WATER.
WARNING: CHILDREN AND
ADULTS SHOULD BE ALERTED
TO THE HAZARDS OF HIGH
SURFACE TEMPERATURE AND
SHOULD STAY AWAY TO AVOID
BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM
AS THE APPLIANCE.
MAINTENANCE
INSTRUCTIONS
Any maintenance required accessing the
glass door of the unit must be performed
by an authorised service person.
1. Always unplug the power cord before
cleaning. For relighting, refer to lighting
instructions. Keep the burner and control
compartment clean by brushing and vacu-
uming at least once a year. When cleaning
the logs, use a soft clean brush as the logs
are fragile and easily damaged.
2. Clean glass (never when unit is hot), appli-
ance, louvres, and door with a damp cloth.
Never use an abrasive cleaner. The gold
louvres (and optional gold door) may be
scratched if abrasives are used to clean
them.
The heater is finished in a heat resistant
paint and should only be refinished with
heat resistant paint (not with wall paint).
Regency uses StoveBright Paint - Metallic
Black #6309.
3. Make a periodic check of burner for proper
position and condition. Visually check the
flame of the burner periodically, making sure
the flames are steady; not lifting or floating.
If there is a problem, call an authorised
service person.
4. The appliance and flueing system must be
inspected before use, and at least annu-
ally, by an authorised field service person,
to ensure that the flow of combustion and
ventilation air is not obstructed.
During the annual service call, the burners
should be removed from the burner tray and
cleaned. Replace the embers - do not block
the pilot or burner ports.
5. Keep the area near the appliance clear and
free from combustible materials, gasoline
and other flammable vapours and liquids.
6. Verify proper operation after servicing.
Handling of Ceramic fiber log sets and brick
panels
When installing or removing ceramic fiber log sets
or ceramic brick panels (if installed) from an appli-
ance we recommend that you use latex gloves and
a P1 respiratory filter be used.
We also recommend if when servicing the appliance
that any items which may be replaced, not be broken
up and are sealed within a heavy duty polythene
bag and labeled as RCF waste.
A vacuum with a HEPA filter should be used when
cleaning up remaining dust or broken bits.
Protective clothing is not required when handling
these articles.
RCF waste is classed as stable, nonhazardous
waste which may be disposed of at any licensed
landfill site.