16
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
Diagram 2
Diagram 3
4)
The latches should already be at the
proper setting. If they are too hard or too
easy to close, you may want to adjust
them by loosening the locking nut and
turning the latch catch. See diagram 3.
5)
Remove the blue plastic protective coat-
ing from the glass.
6)
Test the seal around the door by placing
a piece of paper between the unit and the
door, close the door and try to pull the
paper out. If it slips out easily, then the
door is not properly sealed. Tighten or
loosen the latch by turning the latch catch
inward or outward. See diagram 3.
Note: The door latch may require ad-
justment as the door gasket ma-
terial compresses after a few
fires and after glass replace-
ment. Turn the latch catch in-
ward or outward.
Diagram 1
DOOR INSTALLATION
(Packaged Separately)
1)
Open the two side panels.
2)
Slide the door
onto the two
hinge pins mak-
ing sure the
two pieces are
flush together.
See diagram
Cutout
Pin
Notch
D)02-46
B)02-56
A)02-65
E)02-45
Bracket
A)02-65
The bottom right edge of Log G)02-48 must
sit snugly against the bracket
Side View
G)02-48
E)02-45
F)02-47
1.
3)
Close the door. The
latch plate must be
centered around the
alignment pin. See dia-
gram 2. If the latch plate
interferes with the cor-
ner of the stove you may
want to angle the plate
slightly so the door clos-
es easier.
7)
Place the Left Top Log D)02-46 on the pin
on Log B)02-56 and on top of the cutout on
Log A)02-65.
E)02-45
C)02-44
8)
Place Front Right Log E)02-45 on the two
pins as shown.
9)
Place the lava rock in the area between the
left and right logs, leaving a space in the
middle for log (F) 02-47.
Cutout
Notch
F)02-47
E)02-45
10)
Place the notch in Center Log F)02-47 over
Log E)02-45 and across the cutout on Log
A)02-65.
11)
Position notch in Front Right Log G)02-48 on
Log F)02-47 and push the bottom right edge
against the bracket on the burner tray.
G)02-48
12)
Test fire to ensure proper light off (make sure
flame flows smoothly from one end of burner
to the other. If there is any flame hesitation,
check that area for any blockage of the burner
port.
F)02-47
E)02-45
A)02-65
G)02-48
D)02-46
B)02-56
C)02-44
INSTALLATION