FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
11
Diagram 5
Diagram 4
HORIZONTAL INSTALLA-
TIONS
1)
Set the unit in its desired location. Check to
determine if wall studs are in the way when the
fluing system is attached. If this is the case, you
may want to adjust the location of the unit.
2)
Assemble the desired combination of pipe and
elbow to the appliance adapter with pipe seams
oriented down. Offset the pipe seams as double
seams in one place will cause the outer pipe to
take an oval shape. Kit comes complete with
18" (457mm) of straight flue - 6-5/8" (168mm)
dia. black outer pipe and 4" (102mm) dia. inner
NOTE: For Snorkel terminations in ABOVE
grade installations, follow national or
local code requirements.
Diagram 3
flue.
3)
With the pipe attached to the stove, slide the
stove into its correct location, and mark the
wall for a 9-1/2" (241mm) (inside dimensions)
round hole. The center of the round hole should
line up with the centerline of the horizontal pipe,
as shown in diagram 1. Cut and frame the
9-1/2 (241mm) round hole in the exterior wall
where the flue will be terminated. If the
wall being penetrated is constructed of
non-combustible material, i.e. masonry
block or concrete, a 7" (178mm) diam
-
eter hole is acceptable.
Note:
a)
The horizontal run of flue should
have a 1/4 inch (6mm) rise for every
1 foot (305mm) of run towards the
termination. Never allow the flue to
run downward. This could cause
high temperatures and may present
the possibility of a fire.
b)
The location of the horizontal flue
termination on an exterior wall must
meet all local and national building
codes, and must not be blocked
or obstructed. For External Flue
Terminal Locations, see diagram
on page 7.
c)
Snorkel Terminations:
For installations requiring a vertical
rise on the exterior of the building,
Astro Riser Vent Terminations as
shown in Dia. 2 is available. Follow
the same installation procedures
as used for standard Horizontal
Termination.
NEVER install the Astro Riser vent
upside down.
Below Grade Snorkel Installation
If the Snorkel Termination must be
installed below grade, i.e. basement
application, proper drainage must
be provided to prevent water from
entering the Snorkel Termination.
Refer to Dura-Vent Installation in-
structions for details.. Do not attempt
to enclose the Snorkel within the
wall, or any other type of enclosure.
4)
Install wall penetration heat shield in
the center of the 9-1/2" (241mm) round
hole and attach with wood screws. The
four wood screws provided should be
replaced with appropriate fasteners for
stucco, brick, concrete, or other types
of sidings. Dia. 3.
5)
If installing termination on a siding
covered wall, a vinyl siding standoff or fur
-
ring strips must be used to ensure that the
termination is not recessed into the siding.
Dia. 3.
6)
Take the Riser Vent terminal and separate
the Backing Plate from the Riser Vent Front
by removing 8 screws as shown in diagram
4.
7)
Install the Backing Plate into the wall
penetration heat shield and attach using 4
screws. Dia. 4.
8)
Connect all pipe sections to unit and install
into wall:
INSTALLATION