16
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
Diagram 2
Diagram 3
DOOR INSTALLATION
(Packaged Separately)
1)
Open the two side panels.
2)
Slide the door onto the two hinge pins
making sure the two pieces are flush
together. See diagram 1.
3)
Close the door. The latch plate must be
centered around the alignment pin. See
diagram 2. If the latch plate interferes with
the corner of the stove you may want to
angle the plate slightly so the door closes
easier.
4)
The latches should already be at the proper
setting. If they are too hard or too easy
to close, you may want to adjust them by
loosening the locking nut and turning the
latch catch. See diagram 3.
Diagram 1
5)
Remove the blue plastic protective coating
from the glass.
6)
Test the seal around the door by placing a
piece of paper between the unit and the door,
close the door and try to pull the paper out.
If it slips out eas-
ily, then the door
is not properly
sealed. Tighten
or loosen the
latch by turn
-
ing the latch
catch inward
Cutout
Pin
Notch
D)02-46
B)02-56
A)02-65
E)02-45
Bracket
A)02-65
The bottom right edge of Log G)02-48 must sit
snugly against the bracket
Side View
G)02-48
E)02-45
F)02-47
or outward.
See diagram 3.
Note: The door latch
may require ad-
justment as the
door gasket materi-
al compresses after
a few fires and after
glass replacement.
Turn the latch catch
inward or outward.
on Log B)02-56 and on top of the cutout
on Log A)02-65.
8)
Place Front Right Log E)02-45 on the two
E)02-45
C)02-44
pins as shown.
9)
Place the lava rock in the area between
the left and right logs, leaving a space in
the middle for log (F) 02-47.
10)
Place the notch in Center Log F)02-47 over
Cutout
Notch
F)02-47
E)02-45
Log E)02-45 and across the cutout on Log
A)02-65.
11)
Position notch in Front Right Log G)02-48 on
Log F)02-47 and push the bottom right edge
against the bracket on the burner tray.
12)
Test fire to ensure proper light off (make sure
G)02-48
flame flows smoothly from one end of burner
to the other. If there is any flame hesitation,
check that area for any blockage of the burner
port.
F)02-47
E)02-45
A)02-65
G)02-48
D)02-46
B)02-56
C)02-44