20
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
NORMAL OPERATING
SOUNDS OF
GAS APPLIANCES
It is possible that you will hear some sounds
from your gas appliance. This is perfectly normal
due to the fact that there are various gauges
and types of steel used within your appliance.
Listed below are some examples. All are
normal
operating sounds
and should not be considered
as defects in your appliance.
Blower:
Regency gas appliances use high tech blowers
to push heated air farther into the room. It is not
unusual for the fan to make a "whirring" sound
when ON. This sound will increase or decrease
in volume depending on the speed setting of
your fan speed control.
Burner Tray:
The burner tray is positioned directly under the
burner tube(s) and logs and is made of a differ
-
ent gauge material from the rest of the firebox
and body. Therefore, the varying thicknesses of
steel will expand and contract at slightly different
rates which can cause "ticking" and "cracking"
sounds. You should also be aware that as there
are temperature changes within the unit these
sounds will likely re-occur. Again, this is normal
for steel fireboxes.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will
expand and contract at different rates resulting
in some "cracking" and "ticking" sounds will be
heard throughout the cycling process.
SUMMARY OF
CONTROLS
On/Off Button:
If the unit is switched off, pressing and releasing
this button once will switch the unit on. The unit
will resume its last settings.
If the unit is switched on, pressing and releasing
this button once will switch the unit off.
Flame:
Increase -
If the unit is switched on, pressing
and releasing the flame plus (+) button once will
increase the flame height to the next available
high setting.
Decrease -
If the unit is switched on, pressing
and releasing the flame minus (-) button once
will decrease the flame height to the next avail
-
able low setting.
Fan:
Increase -
If the unit is switched on, pressing
and releasing the fan plus (+) button once will
increase the fan speed to the next available
high setting.
Decrease -
If the unit is switched on, pressing
and releasing the fan minus (-) button once will
decrease the fan speed to the next available
low setting.
PILOT ADJUSTMENT
Periodically check the pilot flames. The correct
flame pattern has 3 strong blue flames.
One flowing around the thermocouple, the
second flowing across the rear of the burner (it
does not have to be touching the burner) and the
third flame flowing tangent to the spark ignitor.
NOTE:
If you have an incorrect flame pat
-
tern, contact your Regency dealer for further
instructions.
Rear of Burner
Front of Burner
An incorrect flame pattern will have small,
probably yellow flames, not coming into
proper contact with the rear of the burner or
thermopile.
Rear of Burner
Front of Burner
OPERATING INSTRUCTIONS