INSTALLATION
FLUING ARRANGEMENTS - VERTICAL TERMINATIONS
FOR BOTH RESIDENTIAL & MANUFACTURED HOMES/MOBILE HOMES
Vertical Terminations
Offset to Vertical Terminations
If connecting to a Dura-Vent system,
the Adapter to Dura-Vent # 640-994
is required.
Vertical Terminations
with Co-linear Flex System
The shaded area in the diagram shows the allowable vertical
terminations installed in a masonry chimney.
All vertical flue instal
-
lations require the Flue Restrictor to be set to 32mm open. All Vertical
Flue Terminals must be Simpson Dura Vent (Abey Australia) DV 980
MAS (Australian Modified.)
using Dura-Vent Fluing System
The shaded areas in the two diagrams below show all allowable com-
binations of straight vertical and offset to vertical runs with vertical
terminations.
Maximum one 90
o
elbow
. All vertical and offset to vertical
flue installations require Flue Restrictor to be set to 32mm open. If the flue
is ENCLOSED in a chase (min. size 229mm x 229mm) maintain a 32mm
clearance to combustibles. All Vertical Flue Terminals must be Simpson
Dura Vent (Abey Australia) DV 980 MAS (Australian Modified.)
Straight Vertical Terminations
Flue Restrictor Position
Vent Restrictor
Vent
Restrictor
Plate
Vent Restrictor
(fully open)
Vent
Restrictor
Plate
44.5mm
44.5mm
32mm
32mm
To set the Flue restriction
as indicated in the diagram,
simply loosen the screws
and push the flue restrictor
plate to the correct position.
Tighten the screws.
216mm
9.1m
Max.
3.2m
Min.
1
1
1
2
4
5
6
7
8
2
1
3
9
Horizontal Distance (meters)
V
ertical
Height
(meters)