Regency FG39-1 FireGenie Freestanding Gas Stove
13
DURA-FLUE
TERMINATION KIT
Planning Your Dura-Flue
Installation
There are two basic types of Dura-Flue Room
Sealed System installations: horizontal termi
-
nation and vertical termination. Confirm the
maximum horizontal run and maximum vertical
rise from the diagrams on page 9.
When planning your installation, it will be nec
-
essary to select the proper length of flue pipe
for your particular requirements. For horizontal
installations, determine the minimum clearance
from the rear of the unit to the wall. It is also
important to note the wall thickness. (The wall
thimble is suitable for 2 x 4 or 2 x 6 / .6m x 1m or
.6m x 2m wall construction.) Select the amount
of vertical rise desired for "vertical-to-horizontal"
type installations.
Warning: Always maintain required clear-
ances (air spaces) to nearby combustibles
to prevent a fire hazard. Do not fill air spaces
with insulation.
The minimum clearance requirements between
the outer wall of the flue pipe and nearby com
-
bustible surfaces is 32mm. Be sure to check
the flue termination clearance requirements
from decks, windows, soffits, gas regulators, air
supply inlets and public walkways as specified
in the Exterior Flue Termination Locations on
page 8 and in your local building codes.
To determine the length of flue pipe required
for vertical installations, measure the distance
from the unit flue outlet to the ceiling, the ceiling
thickness, the vertical rise in an attic or second
storey, and allow for sufficient vertical height
above the roof line.
For multi-storey applications, fire stops are
required at each floor level. If an offset is
needed, additional pipe, elbows and supports
will be required.
Do not exceed the maximum number of elbows.
One 90
o
for horizontal terminations and two 45
o
for vertical termination.
DURA-FLUE FLUING
COMPONENTS
You will require the following components with
your new Regency Room Sealed Freestand
-
ing Gas Stove. Please review your product to
make sure you have everything you need. In
the eflue that you are missing any part, contact
your dealer.
Note: These are the minimum pieces re-
quired. Other parts may be required
for your particular installation. See
below for a list of flue parts.
If installing termination on a siding covered wall,
a vinyl siding standoff or furring strips can be
used in order to ensure that the termination is
not recessed into siding.
The vinyl siding standoff is required for walls
with vinyl siding.
Minimum components for a Dura-Flue
Horizontal Installation:
A) Dura-Flue Horizontal Termination Kit
B) Wall Thimble (required for combus-
tible walls)
Minimum components for a Dura-Flue
Vertical Termination:
C) Dura-Flue Vertical Termination Kit
The Simpson Dura-Flue Room Sealed System
offers a complete line of component parts for
installation of both horizontal and vertical installa
-
tion. Many items are offered in decorative black,
as well as galvanized finish. The galvanized pipe
and fittings are used for concealed locations such
as attics or where corrosion is a factor, such as
INSTALLATION
above the roof line. Decorative brass trim kits
are available for both wall thimbles and ceiling
support boxes.
Part #
Description
971
Horiz. Termination Kit includes:
90
o
black elbow, wall thimble cover,
horiz. square termination cap,
24"
black pipe, 11" -14" 5/8" adjust
able
black pipe
970
Basic Horiz. Termination Kit
includes: 90
o
black elbow, wall
thimble cover, horiz. square
termination cap
978
Vert. Termination Kit includes
0/12 - 6/12 pitch adjustable
flashing, storm collar, low profile
term. cap
908B
6" (152mm) Pipe Length-Black
907B
9" (229mm) Pipe Length-Black
906
12" (304mm) Pipe Length Galv.
906B
12" (304mm) Pipe Length-Black
904
24" (610mm) Pipe Length Galv.
904B
24" (610mm) Pipe Length-Black
903
36" (914mm) Pipe Length Galv.
903B
36" (914mm) Pipe Length-Black
902
48" (1219mm) Pipe Length Galv.
902B
48" (1219mm) Pipe Length-Black
911B
11"-14 5/8" (219mm - 372mm)
Adj. Pipe Length-Black
917B
17"- 24" (432mm - 610mm)
Adj. Pipe Length Black
945 45
O
Elbow Galv.
945B
45
O
Elbow-Black
945G 45
O
Elbow-Swivel Galv.
Dura-Flue Basic
Horizontal Kit # 970
1 90
o
Elbow
1 Wall Thimble Cover
1 Astro Cap