Regency GF900C-1 Gas Fireplace
installation
Vent Guard - if required*
(Part #946-506/P)
(102mm)
Notes:
1) Liner sections should be continuous without any
joints or seams.
2) Only Flex pipe purchased from Regency
®
may be
used for Flex installations
3) Horizontal flue must be supported every 0.9m.
4) Regency
®
Direct Flue System (Flex) is only approved
for horizontal terminations.
5) Flex system can only be used up to a maximum
continuous flue length of up to 3m. If longer runs
are required, rigid pipe must be used.
HORIZONTAL TERMINATIONS
FLEX FLUE 4" X 6-7/8
" (
102MM X 175MM)
These flueing systems, in combination with the GF900 Direct Flue Gas Fireplace, has been tested and listed as a direct flue heater system by Warnock
Hersey/ Intertek. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram in "Exterior Flue Termination
Locations" section.
Regency
®
Direct Flue (Flex) System Termination Kits includes all the parts needed to install the GF900 using a flexible flue.
FPI Kit #
Length
Contains:
#946-515
1.2 m
1)
6-7/8” flexible outer liner (Kit length)
2)
4” flexible inner liner (Kit length)
3)
spring spacers
4)
thimble
5)
AstroCap
termination cap
6)
screws
7)
tube of Mill Pac
8)
plated screws
9)
S.S. screws #8 x 1-1/2” drill point
#946-516
3 m