Regency GF900C-1 Gas Fireplace
35
installation
919-616
11.17.15
FACEPLATE AND DEFLECTOR INSTALLATION
WARNING: Turn off the unit by way of the wall switch
or remote. Allow unit to cool at least 10 min. - prior to
removing the faceplate.
NOTE: There are 3 mounting slots available, this is to accommo-
date any finishing that protrudes slightly beyond the faceplate.
2. Install deflector by using 4 screws provided to the
underside
of
the fascia as shown in Diagram 3 and 4.
It is recommended that you use the first mounting slot (the one clos-
est to the door frame overlay) out of the 3 so that the faceplate and
door frame overlay are flush with one another. See diagram 2.
1. Install the fascia to the unit by hooking the left and right
side mounting brackets into the mounting slots at the side
ofthe firebox as shown below.
Diagram 3
Diagram 4
Deflector
Installed
NOTE: When installing the stainless steel fascia, gloves
should be worn to prevent finger prints.
3 Mounting Slots
Diagram 1
4 screws
Diagram 2
3. Hook the inner door frame to the unit.
Refer to next
page “Screen and Inner Door Frame Installation” prior
to installing it on to the unit.
4. Remove any finger prints/ marks prior to operating
the unit.
1
GF900
FACEPLATE AND DEFLECTOR INSTALLATION
(GF900L shown in the pictures)