16
|
F2452 Regency Freestanding Wood Fire
installation
Flue Baffle &
Secondary Air Tube
Installation
The flue baffle system located in the upper area of the firebox is removable
to make cleaning your chimney system easier. The baffles must be installed
prior to your first fire.
Smoke spillage and draft problems may occur if
the baffles are improperly positioned.
Check the position of the baffles on a
regular basis as they can be dislodged if too much fuel is forced into the firebox.
The unit arrives with the 2 baffles and 2 air tubes on the floor of the firebox.
1. Open the door and remove stainless steel smoke deflector - See smoke
deflector instructions in this manual.
2. Remove the front secondary air tube with pliers as shown below.
4 . Install the 2 front secondary air tubes with pliers and hammer to lock them
into place, as shown below.
3.
Tilt the left baffle up on top of the side channel and it will leave enough
room to position the right baffle in the same manner as Step 1 above.
Then reposition the left baffle flat on the air tubes.
Important:
push both baffles so they are tight against the side walls.
Front View
Front View
Smoke
deflector
2. Slide the left baffle over the 2 remaining air tubes from the front and then
push it to the back.
Side View
5. Reverse Step 1.
Summary of Contents for Hamilton F2452
Page 13: ...F2452 Regency Freestanding Wood Fire 13 installation ...
Page 36: ...36 F2452 Regency Freestanding Wood Fire warranty ...
Page 37: ...F2452 Regency Freestanding Wood Fire 37 notes ...
Page 38: ...38 F2452 Regency Freestanding Wood Fire notes ...
Page 39: ...F2452 Regency Freestanding Wood Fire 39 dimensions ...