AIR SHUTTER ADJUSTMENT:
The L965E/ HZ965E is setup to work with two (2) gas orifices. The orifice on the left (looking from the front) feeds the front burner while the right feeds the
rear burner, which can also be switched off using the remote control.
Each orifice has its own Air Shutter. The Air Shutter is connected to an Adjustment Lever that is accessible from the front and bottom of the firebox. These
Air Shutters can be adjusted during the operation of the fireplace.
This Figure 68 shows the fireplace with the door and the burners removed. This is to better show the Air Shutters and the Adjustment Levers. The Door/Air
Shutter Tool (see Figure 116) has a small slots on one end. These slots can be used to engage the vertical section of the adjustment lever to move the klever
forward or rearward. Moving the Lever towards you opens the Air Shutter, while moving it rearward, closes the Air Shutter.
Air shutters should be adjusted so that the gas flame burns with a blue base and a bright yellow upper section. Air shutters set to closed will lead to a dirty
flame which may lead to soot gathering on the logs and/or glass panel. Properly set Air Shutters will result in a very blue flame for the first fifteen (15) minutes
of operations with the flame becoming more yellow as the unit comes up to operating temperature.
Table 2: Air Shutter Settings.
Left
Right
Glass / Media Burner
LP
Open
Open
NG
Open
Open
Log Set/ Ember Bed Burner
LP
Open
1/8” (3mm) Open
NG
Open
1
/
16
” (2mm) Open
Figure 116: Air Shutter Adjustment.
Ignition Information
1
. The Proflame DFC Board will try two (2) times for ignition.
2
. Each try for ignition will last 60 seconds.
3
. The wait time between the two tries is 35 seconds.
4
. If the appliance does not light after the second try for ignition (60 second duration) the appliance will go into lockout.
5
. To remove appliance from lockout:
• Locate the receiver on the wall and move the slide switch to the
<OFF>
position for a minimum of 2 seconds.
• After 2 seconds, slide the switch back to
<REMOTE>
and/or
<ON>
position and retry.
HZ965/L965 Gas Fireplace |
59
59
|
operating instructions
Summary of Contents for Horizon HZ965E
Page 52: ...SAFETY SCREEN INSTALLATION 52 HZ965 L965 Gas Fireplace 52 installation ...
Page 66: ...66 HZ965 L965 Gas Fireplace 66 parts list ...
Page 72: ......
Page 73: ...HZ965 L965 Gas Fireplace 73 73 notes ...
Page 74: ...74 HZ965 L965 Gas Fireplace 74 notes ...
Page 75: ......