188
June 2007 Regency Product Specifi cations Book
W
ood Inser
ts
Wood Inserts
I1200 Wood Insert
Dimension Description
I1200
A
Adjacent Side Wall (to side)
15” (381mm)
B
Mantle (to top)**
20” (508mm)
C
Top Facing (to top)
14” (356mm)
D
Side Facing (to side)
7-3/8” (187mm)
E
Minimum Hearth Extension*
16” (406mm)
F
Minimum Heath Thickness*
1-1/2” (38mm)
G
Minimum Hearth Side Extension
8” (203mm)
Side and Top facing is a maximum of 1-1/2" thick.
Floor protection must be non-combustible, insulating material with an
R value of 1.1 or greater.
*
If the hearth extension is fl ush with the fl oor (F) it must extend
19-1/2" in front of the body face (E).
Note: Hearth Extension Width (G) is measured from edge of fuel
door to side of hearth.
** A non-combustible mantel may be installed at a lower height if the
framing is made of metal studs covered with a non-combustible
board.
I1200 Small Wood Insert