Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
29
OPERATING INSTRUCTIONS
OPERATING
INSTRUCTIONS
Before operating this appliance, proceed through
the following check list.
1)
Read and understand these Instructions
before operating this appliance.
2)
Check to see that all wiring is correct and
enclosed to prevent possible shock.
3)
Check to ensure there are no gas leaks.
4)
Make sure the three pieces of door glass
are properly positioned. Never operate the
appliance with any of the glass removed or
with the door open.
5)
Verify that all flueing and the cap is unob
-
structed.
6)
Verify log placement.
LIGHTING
INSTRUCTIONS
1)
Plug the power cord into a power outlet.
2)
Press and release the ON/OFF button once
to start the unit.
3)
After approximately 3 seconds the spark
ignition system will spark for 40 seconds to
light the main burner.
4)
If the main burner does not light, reset the
unit.
ADJUSTING FLAME
HEIGHT
There are six flame settings that can be adjusted
by pressing and releasing the plus (+) and minus
(-) FLAME button.
The FLAME setting button is located on the
control panel in behind the pedestal door.
FAN OPERATION
Set the fan speed on the control panel located
in behind the bottom louvre.
Pressing and releasing the plus (+) FAN button
will change the fan speed as follows:
OFF -> LOW -> MEDIUM -> HIGH -> OFF, etc.
Pressing and releasing the minus (-) FAN button
will be the reverse of the above.
RESETTING
THE UNIT
1)
Open the bottom louvre of the unit.
2)
Press and release the reset button, located
on the unit's control panel once.
3)
Wait for approximately 3 seconds and the
pilot sparks can be heard and seen. It would
take 2 to 3 seconds for the flame to be lit.
NOTE:
A period of 30 seconds must pass before
another reset is attempted.
SHUTDOWN
INSTRUCTIONS
1)
Press the ON/OFF button once.
2)
Turn off all electric power to the appliance
if service is to be performed.