Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
34
MANUAL CONTROL REPLACEMENT
1) Unplug the power source.
2)
Open the bottom louver.
5)
Remove the valve heat shield by undoing the 2 screws.
Valve Heat Shield
6)
Pull out the ECS box by carefully lifting it up off the velcro.
7)
Remove the ECS box cover by undoing the 3 screws.
8)
Unplug in the CAT5 cable of the manual control box from the con
-
nector in the ECS box.
Manual Control Box
Louver Bracket
ECS Box
3)
Undo the 3 screws to remove the manual control box from the
louver.
4)
Remove the louver bracket from the manual control box by undoing
one screw.
9)
Plug the replacement manual control switch CAT5 cable into the
connector in the ECS box.
10)
Re-install the cover on the ECS box. Ensure to fit the rest of the cable
into the groove in the ECS box.
11)
Put the ECS box back in place under the firebox.
12)
Reverse steps 5 to 1.
MAINTENANCE