FIRST FIRE
The first fire in your stove is part of the paint curing
process. To ensure that the paint is properly cured,
it is recommended that you burn your fireplace for
at least four (4) hours the first time you use it with
the fan on. When first operated, the unit will release
an odour caused by the curing of the paint, the
burning off of any oils remaining from manufacturing.
Smoke detectors in the house may go off at this
time. Open a few windows to ventilate the room for
a couple of hours.
The glass panel may require cleaning after the unit
has cooled down.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS HOT.
Note: When the glass is cold and the appliance
is lit, it may cause condensation and fog
the glass. This condensation is normal
and will disappear in a few minutes as
the glass heats up.
OPERATING
INSTRUCTIONS
1. Read and understand these instructions before
operating this appliance.
2. Check to see that all wiring is correct and
enclosed to prevent possible shock.
3. Check to ensure there are no gas leaks.
4. Make sure the glass in the door frame is properly
positioned. Never operate the appliance with
the glass removed.
5. Verify that the venting and cap are unobstructed.
6. Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have been
incorrectly positioned.
7. The unit should never be turned off, and on
again without a minimum of a 60 second wait.
8. Hook up remote receiver to wire marked 'receiver'
which will be located on the bottom of the appli-
ance. This remote control requires coding. See
remote control instructions for details.
During the first few fires, a white film
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the film will bake on and
become very difficult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.
Proflame
video
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
NOTE:
This appliance will operate during power
outages. Only the fan will not operate until power
is restored. If the remote batteries in both the
handheld transmitter or receiver lose power, the
appliance can still be operated by sliding the
switch on the receiver switch from "Remote"
to "ON". To turn on the appliance off slide the
receiver switch from "ON" to "Remote" or "OFF".
IMPORTANT:
The remote control system supplied
with this appliance has several options for start-
ing/operating the appliance, please read the
remote control operating instructions (packed
with remote control) to understand how to
operate this remote system. You can download
remote functions video with the QR code below..
LIGHTING
PROCEDURE
Important: If the pilot does not hold, turn pilot knob
to "OFF" position. Wait 5 minutes to clear gas. If
you smell gas - STOP! Follow the safety information
above. If you don't smell gas, repeat Steps 1-6.
1. Push in gas control knob slightly and turn to
"PILOT" position.
2. Push in control knob all the way and hold in until
the pilot lights up. Continue to hold the control
knob in until a faint buzzer sound can be heard
for 4 seconds informing the operator that the knob
can now be released. Release knob.
3. Push in gas control knob slightly and turn to
"ON" position.
4. Ensure the receiver is in the remote position.
IMPORTANT
Prior to igniting or re igniting
the pilot, remove the glass
door.
Set Switch to
Remote
Diagram 1
5. Press and release the ON/OFF button on the
remote handheld transmitter. An audible beep
should be heard from the receiver.
ON/OFF
Button
6. The unit will turn on.
SHUTDOWN
PROCEDURE
1. Press "OFF" on the remote or slide receiver switch
from remote to "OFF".
2. Turn the gas control knob to the "OFF" position
to turn off the pilot.
Pilot may be shut off during prolonged non use
periods to conserve fuel.