Regency
®
U39-11 ULTIMATE™ Freestanding Gas Stove
|
41
operating instructions
Fan Speed Control
If the appliance is equipped with a hot air circulating fan, the speed of the fan
can be controlled by the Proflame system. The fan speed can be adjusted
through six (6) speeds. To activate this function use the Mode Key (fig.1) to
index to the fan control icon (Fig. 8). Use the Up/Down Arrow Keys (Fig.1)
to turn on, off or adjust the fan speed (Fig. 9). A single “beep” will confirm
reception of the command.
Figure 9
Figure 8
Remote Actuated 120V Auxiliary Outlet
The auxiliary function controls the AUX power outlet on the Fan Control Module.
To activate this function use the Mode Key (fig. 1) to index to the AUX icon (fig.
10 & 11). Pressing the Up Arrow Key will activate the outlet. Pressing the Down
Arrow Key will turn the outlet off. A single “beep” will confirm the reception of
the command.
Figure 10
Figure 11
Key Lock
This function will lock the keys to avoid unsupervised operation.
To activate this function, press the MODE and UP Keys at the same time (fig. 18).
To de-activate this function, press the MODE and UP Keys at the same time.
LOW BATTERY POWER DETECTION
Transmitter
The life span of the remote control batteries depends on various factors:
quality of the batteries used, the number of ignitions of the appliance, the
number of changes to the room thermostat set point, etc.
When the Transmitter batteries are low, a Battery Icon will appear on the LCD
display of the Transmitter (Fig. 13) before all battery power is lost. When the
batteries are replaced this Icon will disappear.
Receiver
The life span of the Receiver batteries depends on various factors: quality of Fig. 19
the batteries used, the number of ignitions of the appliance, the number of
changes to the room thermostat set point, etc.
When the Receiver batteries are low, No “beep” will be emitted from the
Receiver when it receives an On/Off command from the Transmitter. This is
an alert for a low battery condition for the Receiver. When the batteries are
replaced the “beep” will be emitted from the Receiver when the ON/OFF Key
is pressed (See Initialization of The System).
Figure 12