5
safety decal
This is a copy of the label that accompanies each
ULTIMATE Direct Vent Freestanding Gas Stove. We
have printed a copy of the contents here for your
review. The safety label is located on the inside of
the drop down pedestal door.
NOTE:
Regency
®
units are constantly being
improved. Check the label on the unit and if there is
a difference, the label on the unit is the correct one.
COPY OF SAFETY LABEL FOR U39 GAS STOVE
Minimum Clearances to Combustibles
Dégagements minimaux aux matériaux combustibles
475
Serial No./No de série
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ÉTIQUETTE
A 7-1/2" /190mm
B 6"
/150mm
E 2"
/50mm
Min. Ceiling Height from top of unit / Min. Plafond
Hauteur depuis le haut de l'appareil:
36" / 914 mm
Duplicate serial #
M
od
el/M
od
èle
:
U3
9-N
G
11
M
od
el/M
od
èle
:
U3
9-L
P1
1
475
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title
24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA
501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited
by local codes. See owner's manual for details. Optional Fan (Part# 910-331/P).
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construc-
tion and Safety Standard. Si ces normes ne sont pas pertinentes, se reporter à la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou
NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée mobile installée à demeure si les
règlements locaux le permettent. Voir le manuel d'utilisation pour plus de renseignements. Ventilateur en option (Pièce n
o
910/331/P)
This vented gas fi replace heater is not for use with air fi lters. N e pas utiliser de fi ltre à air avec ce foyer au gaz à évacuation
.
For use with glass doors certifi ed with the appliance only À utiliser uniquement avec les portes vitrées certifiées avec l’appareill
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION - NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE
.
Made in Canada / Fabriqué au Canada
Listed: VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
Certifi ed to/Certifi é :
C# 4001172
For Use Only with Barrier (Part #732-929) Follow installation instructions.
Utiliser uniquement avec l’écran de sécurité (n° 732-929). Suivre les consignes d'installation.
ELECTRICAL SUPPLY/ALIMENTATION ÉLECTRIQUE
:
115V_60HZ less than/Moins de 2 AMP.
FPI Fireplace Products International Ltd. Delta, BC, Canada
FACTORY EQUIPPED FOR NATURAL GAS:
Model U39-NG11
Minimum supply pressure
5"
WC/C.E. (1.25kPa)
Manifold pressure High
3.5" WC/C.E. (0.87kPa)
Manifold pressure Low
1.6"
WC/C.E. (0.40kPa)
Model U39-NG11: Factory Equipped for Altitude 0-2000 ft.
Orifi ce size
#36
DMS
Altitude
0-2000 ft/pi
(0-610)
Maximum Input
33,500 Btu/h (9.81Kwh)
Minimum Input
23,500 Btu/h (6.88Kwh)
Model U39-NG11: Convertible for Altitude 2000-4500 ft.
Orifi ce size
#37
DMS
Altitude
2000-4500ft/pi (610-1370m)
Maximum Input
31,000 Btu/h (9.08Kw)
Minimum Input
22,000 Btu/h (6.44Kwh)
FACTORY EQUIPPED FOR PROPANE GAS:
Model U39-LP11
Minimum supply pressure
11"
WC/C.E. (2.74Kpa)
Manifold pressure High
10"
WC/C.E. (2.49Kpa)
Manifold pressure Low
6.4"
WC/C.E. (1.59Kpa)
Orifi ce size
51
DMS
Altitude
0-2,000 ft/pi
(0-610m)
Maximum Input
32,500 BTU/h (9.52Kw/h)
Minimum Input
26,000 BTU/h (7.76Kw/h)
Model U39-LP11: Convertible for Altitude 2000-4500 ft.
Orifi ce size
#52
DMS
Maximum Input
29,000 Btu/h (8.49Kwh)
Minimum Input
24,500 Btu/h (7.18Kwh)
APPAREIL FONCTIONNANT AU GAZ NATUREL :
Modèle U39-NG11
Pression d’alimentation minimale
Pression manifold élevée
Pression manifold basse
Fonctionnant à une altitude entre 0 et 2000 pi :
Dimensions de l’orifi ce
Altitude
Débit calorifi que maximal
Débit calorifi que minimal
Convertible pour altitude entre 2000 et 4500 pi :
Dimensions de l’orifi ce
Altitude
Débit calorifi que maximal
Débit calorifi que minimal
APPAREIL FONCTIONNANT AU PROPANE :
Modèle U39-LP11
Pression d’alimentation minimale
Pression manifold élevée
Pression manifold basse
Dimensions de l’orifi ce
Altitude
Débit calorifi que maximal
Débit calorifi que minimal
Convertible pour altitude entre 2000 et 4500 pi :
Dimensions de l’orifi ce
Débit calorifi que maximal
Débit calorifi que minimal
919-915
CSA P.4.1 Fireplace Efficiency (FE) /Efficacité énergétique des foyers (EEF) CSA P.4.1
Natural Gas / Gaz naturel 69.85%
Propane Gas / Gaz propane 71.60%
CANADIAN ENERGY
PERFORMANCE
VERIFIED
RENDEMENT
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
Part #: 919-915
Colour: Black on Grey except selected text
is in red as per this print.
Material: 2ml silver matt polyester (DPM SMS)
Size: 100%
Sept 24/18: Created Decal
Oct. 17/18: Updated decal data
Nov. 27/18: Added efficiencies
Apr. 04/19: Updated efficiencies
* Printer: Start serial sequence at 475000001
ANSI Z21.88-2017 • CSA 2.33-2017 / CSA 2.17-2017
For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth
of Massachusetts.
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm
with battery back up in the same room where the gas appliance is installed.
Summary of Contents for U39-LP11
Page 49: ...Regency U39 11 ULTIMATE Freestanding Gas Stove 49 notes ...
Page 54: ......
Page 55: ......