Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove
21
U39-NG: For 0 to 2000 feet altitude
U39-LP: For 0 to 4500 feet altitude
Burner Inlet Orifice Sizes:
Natural Gas Propane
Burner
#32
#50
Max. Input -
Natural Gas/Propane
38,000 Btu/h
Min. Input -
Natural Gas/Propane
20,000 Btu/h
Supply Pressure
Natural Gas
min. 5" w.c.
Propane
min. 12" w.c.
Manifold Pressure
Natural Gas
3.8"
+/- 0.2" w.c.
Propane
11"
+/- 0.2" w.c.
Electrical: 120 V. 1.13A 60Hz.
Circulation: Variable speed fan, 125/75 CFM.
Log Set: Ceramic fiber, 7 per set.
System Data:
HIGH ELEVATION - U39-NG
For 2,000 - 4,500 feet altitude
Burner Inlet Orifice Sizes:
Natural Gas
Burner
#33
Max. Input Rating
36,100 Btu/h
Min. Input Rating
19,000 Btu/h
System Data
U39 Converted to 30,000 Btu
For 0 to 4500 feet altitude
Burner Inlet Orifice Sizes:
Natural Gas
Propane
Burner
#37
#52
Max. Input -
Natural Gas/Propane
30,000 Btu/h
Min. Input
- Natural Gas/Propane
15,000 Btu/h
Supply Pressure
Natural Gas
min. 5" w.c.
Propane
min. 12" w.c.
Manifold Pressure
Natural Gas
3.8" +/- 0.2" w.c.
Propane
11" +/- 0.2" w.c.
Electrical: 120 V. 1.13A 60Hz.
Circulation: Variable speed fan, 125/75 CFM.
Log Set: Ceramic fiber, 7 per set.
System Data
U39 with 40,000 BTU
GAS CONNECTION
The gas connection is a 3/8" NPT 90
o
elbow. The
gas line can be rigid pipe or to make installation
easier, use a listed flexible connector and/or
copper tubing if allowed by local codes. Since
some municipalities have additional local codes
it is always best to consult with your local
authorities and the CAN/CGA B149 installation
codes.
For USA installations follow local codes and/or
the current National Fuel Gas Code, ANSI
Z223.1.
When using copper or flex connectors use only
approved fittings. Always provide a union so
that gas lines can be easily disconnected for
burner and/or valve servicing. Flare nuts for
copper lines and flex connectors are usually
considered to meet this requirement.
I
mportant: Always check for gas leaks
with a soap and water solution or gas leak
detector. Do not use open flame for leak
testing.
Note: Prior to any pressure testing of
the gas supply piping system that
exceeds test pressures of 1/2 psig,
this appliance must be disconnect-
ed from the piping system. If test
pressures equal to or less than 1/
2 psig are used then this appliance
must be isolated from the piping
system by closing its individual
manual shut-off valve during the
testing.
HIGH ELEVATION
This unit (at 38,000 Btu/h) is approved in Can-
ada for altitude 2000 ft. to 4500 ft. (CAN/CGA-
2.17-M91) with the orifice kit Part # 621-975. For
Natural Gas installations above 4500 ft. follow
current CAN/CGA-B149.1.
In U.S.A., for installations above 2000 ft. refer
to current ANSI Z223.1 Sc8-8.1.2a appendix F,
for resizing orifice.
INSTALLATION
Diagram 9
9) Slide the Wall Thimble Cover (Part # 940)
over the Retro Connector and secure with
masonry bolts. Diagram 10. If you have a
framed wall in front of the masonry, use
wood screws to mount the Wall Thimble
Cover to the framed wall, over the Retro
Connector and the 10" (254mm) square
framed opening. Diagram 11. If needed, add
a section of direct vent pipe to the Retro
Connector in order to extend through the
opening in the Wall Thimble Cover.
Diagram 10
Diagram 11
10) The connection between the appliance and
the Retro Connector may be completed with
a section of black direct vent pipe, together
with an adjustable length pipe section.