background image

Regency Z30 scanner 
 
To program the Search function on the Regency Z30

:

  

 
1: Press the 'Program' button  
2: Enter a frequency  
3: Press 'enter'  
4: Press #1 to enter your frequency as the low boundary  
Press #2 to enter your frequency as the hi boundary  
5: Press scan to blind search between the two frequencies  
 
You may use the hold key to force the scanner to stop on any frequency that breaks 
the squelch. If you don't do this, the scanner will stop,  
then continue scanning.  
 
------------------------------------------------------------------------------------------------------- 
------------------------------------------------------------------------------------------------------- 
 
To program Memory Channels 

On the Regency Z30: 

 
TURN UNIT "ON" 
 
1. Press "MANUAL" 
 
2. Enter the frequency you want, example 162.475 
 
3. Press "ENTER" 
 
The display will show "Ch_" with the _ (underscore) flashing 
 
4. Enter the number of the channel where you wish to store the frequency. 
 
Note: channels 1 thru 9 must have a zero before them, example 01, 02,........ 09 
 
If you want to add more frequencies at this time, got to step 2. 
 
To lock out a channel, press "SCAN" and while the unit is scanning,enter the channel 
number. Repeat this action to unlock a channel. 
 
To increase or decrease the scanning rate, press the "SPEED / ENTER" key while the 
unit is scanning. 
 
To create a delay after a transmission, press the "DELAY" key while the unit is 
scanning. 
 
You can change the display by pressing the "CHANNEL / DISPLAY" key. 
 
There are 3 choices: display only the channel number, only the frequency,or alternate 
displaying the channel number and the frequency. 
 