       All safety related  codifications, symbols and instructions that appear in this operating manual 
or on the equipment must be strictly followed to ensure the safety of the operating personnel as 
well as the instrument. 

      If all the equipment is not handled in a manner specified by the manufacturer, it might impair the 
protection provided by the equipment .

=>

 Read complete instructions prior to installation and operation of the unit. 

WARNING

 : Risk of electric shock.

 3)  Cable used for connection to power source, must have a cross section of 1mm or greater. These wires 
       should have insulations capacity made of at least 1.5kV.      

 2) To reduce electro magnetic interference, use wire with adequate rating and twists of the same of equal size shall 
      be made with shortest connection.            

 1) To prevent the risk of electric shock power supply to the equipment must be kept OFF while doing the wiring 
      arrangement. Do not touch the terminals while power is being supplied.  

 4)  A better anti-noise effect can be expected by using standard power supply cable for the instrument.         

1) This equipment, being built-in-type, normally becomes a part of main control panel and such in case the 
    terminals do not remain accessible to the end user after installation and internal wiring.  

2) Do not allow pieces of metal, wire clippings, or fine metallic fillings from installation to enter the product 
     or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator.      
3) Circuit  breaker or mains switch must be installed between power source and supply terminal to 
    facilitate power ‘ON’ or ‘OFF’ function. However this mains switch or circuit breaker must be 
     installed at convenient place normally accessible to the operator.     
4) Use and store the instrument within the specified ambient temperature and humidity ranges as 
     mentioned in this manual.     

Warning Guidelines

Safety Precautions

Installation Guidelines

Mechanical Installation

Maintenance

1) Prepare the panel cutout with proper dimensions as show above.
2) Fit the unit into the panel with the help of clamp given.
3) The equipment in its installed state must not come in close proximity to any heating source, 
    caustic vapors, oils steam, or other unwanted process by products.
4) Use the specified size of crimp terminal (M3.5 screws) to wire the terminal block. Tightening the
     screws on the terminal block using the tightening torque of the range of 1.2 N.m.
5) Do not connect anything to unused terminals. 

   

1) The equipment should be cleaned regularly to avoid blockage of ventilating parts.         

2) Clean the equipment with a clean soft cloth. Do not use isopropyl alcohol or any other cleaning agent.
3) Fusible resistor must not be replaced by operator. 

2

95mm  -  3.75 inches

85mm  -  3.34 inches

136mm  -  5.35 inches

120mm  -  4.72 inches

B

B

A

A

F

E

MODEL

A

96mm

96mm

92mm

92mm

3mm

42mm

B

C

D

E

F

DIMENSIONS

MODEL

A

72mm

72mm

68mm

68mm

3mm

57mm

B

C

D

E

F

DIMENSIONS

C

C

D

D

R

BC 7461

1 2 3 4 5

.

6

1 2 3

.

4

SET

SET

ENT

ENT

RESET

RESET

E

F

MADE IN INDIA

REGENT CONTROL SYSTEMS (I) PVT LTD.

REGENT CONTROL SYSTEMS (I) PVT LTD.

BATCH COUNT

TOTAL

BATCH COUNT

TOTAL

Summary of Contents for BC-9461

Page 1: ...y LOWER 4 Digit 7 seg 0 4 green LED Display LOWER 4 Digit 7 seg 0 4 green LED Display BC 7461 1 Relay 1C O 230V AC 5A Technical Specification Connection Diagram MADE IN INDIA TOTAL TOTAL BATCH COUNT Note 1 For NPN Proxi Short pin 3 4 2 For PNP Proxi Short pin 6 5 3 For Microswitch Short pin 6 5 Proxi Connction to 4 6 5 Proxi Connction to 3 4 5 Micro switch Connection to 3 4 7 8 9 10 5 6 L N 1 2 3 ...

Page 2: ...et of total length SET SET SET MADE IN INDIA Total Batch Count Batch Count Press Key Press Key For Program Press Key Press Key Total Batch Count Batch Count Press Key To save exit Press Key To save exit For Program Ch 1 1 2 3 4 5 6 1 2 3 4 9 9 9 9 9 9 9 9 Ch 2 1 2 3 4 5 6 1 2 3 4 9 9 9 9 9 9 9 9 s e t c t 1 r l y t I m s e t c t 1 s e t c t 2 ...

Page 3: ...ch setting Always set the value of set 1 less then set 2 When it reaches to set count 1 Relay Buzzer will be ON when it reaches to set count 2 Relay Buzzer will be OFF Batch Count will be zero Note Press key and power on the instrument Display will show parameters SLOW MEDIUM FAST Set Speed Selection by Pressing key SLOW MAX RPM 500 MEDIUM MAX RPM 5000 FAST MAX RPM 15000 Press key to save the para...

Page 4: ...turn endanger life or cause electrical shock to the operator 3 Circuit breaker or mains switch must be installed between power source and supply terminal to facilitate power ON or OFF function However this mains switch or circuit breaker must be installed at convenient place normally accessible to the operator 4 Use and store the instrument within the specified ambient temperature and humidity ran...

Reviews: