Sentinel Kinetic Advance S, SX - www.regulus.eu
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE COMMENCING
INSTALLATION.
1. Do not install this product in areas where the following may be present or occur:
• Excessive oil or a grease laden atmosphere.
• Corrosive or flammable gases, liquids or vapours.
• Subject to direct water spray from hoses.
• Ambient temperatures higher than 40 °C and lower than -20 °C.
• Possible obstructions that may hinder access to or removal of the unit.
2. All wiring must be in accordance with the current wiring regulations. Installation should
be inspected and tested by a suitably qualified person after completion.
3. Ensure the mains supply (voltage, frequency and phase) complies with the rating label.
4. The unit should be provided with a local double pole fused spur fitted with a 3A fuse having
a contact separation of at least 3mm. These units must be earthed.
5. Precautions must be taken to avoid the back-flow of gases into the building from the open flue
of gas or other fuel-burning appliances.
6. This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
7. Young children should be supervised to ensure that they do not play with the appliance.